17.02.2015 Aufrufe

Arbeitsanleitung - Milenia Biotec GmbH

Arbeitsanleitung - Milenia Biotec GmbH

Arbeitsanleitung - Milenia Biotec GmbH

MEHR ANZEIGEN
WENIGER ANZEIGEN

Sie wollen auch ein ePaper? Erhöhen Sie die Reichweite Ihrer Titel.

YUMPU macht aus Druck-PDFs automatisch weboptimierte ePaper, die Google liebt.

- 4 -<br />

Summary and Explanation<br />

Being an acute phase protein, C-reaktive protein (CRP) is mainly synthesized in the liver. However, recent<br />

research has shown that the inflammatory protein is also produced in other tissues such as vascular smooth<br />

muscle cells and adipocytes. The expression of CRP is particularly increased in pathologically altered vessels.<br />

The CRP serum level was originally determined to detect and monitor acute inflammation. The value may<br />

increase up to 1000fold under acute inflammatory conditions.<br />

Method and Test Principle<br />

The <strong>Milenia</strong> ® QuickLine CRP test is a lateral flow immunoassay designed for semi quantitative measurement<br />

of human CRP in capillary blood, venous blood, or serum.<br />

The sample is pipetted into the sample application port.<br />

The CRP in patients’ sample binds first to a monoclonal anti-CRP antibody that is conjugated to gold particles.<br />

The CRP-loaded gold particles diffuse through the membrane and pass Test line T. There, a monoclonal CRP<br />

specific antibody is coated on the membrane. At this place the CRP-gold-particels were bound specifically and<br />

become visible as Test line T. The color intensity of the Test line is directly proportional to the concentration of<br />

CRP in the sample. The intensity increases during incubation time. Excess gold conjugate diffuses further over<br />

the test membran. Conjugat-specific antibodies that applied onto the membrane are functioning as Control line<br />

(C). Here the residual gold conjugate is captured and forms a well visible line during the incubation time.<br />

Increasing or decreasing colour’s intensity of the Control line can not be used for any interpretation.<br />

The test unit must be evaluated colourimetrically with the <strong>Milenia</strong> ® POCScan Reader.<br />

The result displayed on the reader is calculated according to a stored standard curve.<br />

<strong>Milenia</strong> <strong>Biotec</strong>, Versailler Straße 1, D-35394 Gießen<br />

<strong>Milenia</strong> QuickLine CRP (MQLRP)

Hurra! Ihre Datei wurde hochgeladen und ist bereit für die Veröffentlichung.

Erfolgreich gespeichert!

Leider ist etwas schief gelaufen!