Arbeitsanleitung - Milenia Biotec GmbH
Arbeitsanleitung - Milenia Biotec GmbH
Arbeitsanleitung - Milenia Biotec GmbH
Sie wollen auch ein ePaper? Erhöhen Sie die Reichweite Ihrer Titel.
YUMPU macht aus Druck-PDFs automatisch weboptimierte ePaper, die Google liebt.
- 3 -<br />
Materials Provided,- Storage and Stability<br />
Preparation Storage at Shelf life<br />
Components Cat.-No. Content<br />
CRP Test Unit:<br />
MQSRP<br />
s<br />
30 ready to use 2 - 8 °C<br />
membrane coated with<br />
Use<br />
monoclonal (mouse) anti-hCRP<br />
immediately<br />
antibody; monoclonal (mouse)<br />
after opening<br />
anti-hCRP antibody conjugated<br />
the foil pouch!<br />
to gold particles<br />
CRP/ hsCRP Chase Buffer:<br />
PBS-Buffer, pH 7.4<br />
This bag contains<br />
30 Transfer pipettes<br />
10 µL, disposables<br />
Certificate of Analysis<br />
MQCBC<br />
1 vial<br />
with 3 ml<br />
(yellow<br />
cap)<br />
in the closed<br />
foil pouch until<br />
expiration date<br />
ready to use 2 - 8 °C until expiration<br />
date<br />
MQP1030 30 see procedure p.5 until expiration<br />
date<br />
CoA-<br />
MQLRP<br />
Material Safety Data Sheets are available on request (look as well www.milenia-biotec.de).<br />
Intended Use<br />
1<br />
• For in vitro diagnostic use.<br />
• <strong>Milenia</strong> ® QuickLine CPR is designed for semi quantitative measurement of human CRP in whole blood and<br />
serum<br />
Materials Required But Not Supplied<br />
Pipet and tips: 5 µL (serum samples)<br />
Specimen Collection and Preparation<br />
Whole blood: capillary blood, venous blood, or serum.<br />
Avoid hemolysis; separate serum from blood cells within two hours.<br />
Whole Blood: avoid blood from clotting e.g with anticoagulants like heparin, EDTA; no citrate.<br />
Volume Required<br />
Whole blood: 10 µL<br />
Serum: 5 µL<br />
Warnings and Precautions<br />
• Read these instructions and the <strong>Milenia</strong> ® POCScan Reader Manual carefully before performing the<br />
test. Follow them step by step!<br />
• Store reagents at 2 - 8° C!<br />
• Do not use the kit after expiration date!<br />
• Do not use test unit if foil pouche is damaged!<br />
• Protect test units from moisture!<br />
• Compare batch code of your kit and the given batch code in your reader; if necessary: change batch<br />
code and parameters. (s. <strong>Milenia</strong> ® POCScan Reader Manual –‘Enter Test Parameters’)<br />
• Do not interchange components of packages of different batch codes!<br />
• All samples, used units, pipettes, tips, and other contaminated material should be handled carefully<br />
and as potentially infectious.<br />
• For professional users.<br />
<strong>Milenia</strong> <strong>Biotec</strong>, Versailler Straße 1, D-35394 Gießen<br />
<strong>Milenia</strong> QuickLine CRP (MQLRP)