EMETRION meters with - Görlitz AG
EMETRION meters with - Görlitz AG
EMETRION meters with - Görlitz AG
Erfolgreiche ePaper selbst erstellen
Machen Sie aus Ihren PDF Publikationen ein blätterbares Flipbook mit unserer einzigartigen Google optimierten e-Paper Software.
EDW.collector<br />
LAN / WAN<br />
ling and monitoring was used as<br />
the core building blocks for the<br />
EDW3000.<br />
DataTranslationServer<br />
DTS<br />
CommandControlServer<br />
CCS<br />
From the ENZ2000<br />
to the EDW3000<br />
This system serves as the platform<br />
for the EDW.collector meter<br />
reading system. The new system<br />
has several new functionalities<br />
that were lacking in the previous<br />
ENZ2000 and it is also compliant<br />
<strong>with</strong> tomorrow’s IT architecture.<br />
The second project step was to<br />
integrate the old data retrieval<br />
software ENZ into the new database<br />
platform EDW, using the<br />
EDW.command development.<br />
Any “old” ENZ2000 can now be<br />
controlled and monitored <strong>with</strong><br />
a “new” EDW3000 system. This<br />
was the prerequisite to enable a<br />
seamless switch from the old to<br />
the new system environment.<br />
T A L K / D AT A<br />
T AL K<br />
ComServer<br />
Flexible resource<br />
management<br />
The third and current project step<br />
is the development and completion<br />
of the new data collection<br />
module EDW.collector to complete<br />
the whole migration process. The<br />
architecture of the new collector is<br />
more flexible in terms of installation<br />
and performance configuration<br />
compared <strong>with</strong> the ENZ2000.<br />
Im Minimalausbau des Systems können<br />
Modemsteuerung, Datenbank und Client<br />
auf einem einzigen PC installiert werden (Foto: GÖRLITZ)<br />
R S C S T R R D T D C D<br />
ISDN<br />
GSM<br />
EDW.engine<br />
EDW.client<br />
Datenbank<br />
T AL K / D A T A<br />
T A L K<br />
R S C S T R R D T D C D<br />
PSTN<br />
1 ... n<br />
DataTranslationServer<br />
DTS<br />
1 .. n<br />
EDW.client(s)<br />
1 ... n<br />
CommandControlServer<br />
CCS<br />
11/2004 METERING automation 27<br />
LAN<br />
1 .. n<br />
EDW.engine<br />
1 ... n<br />
ComServer<br />
T AL K / D AT A<br />
T AL K<br />
R S C S T R R D T D C D<br />
LAN /<br />
WAN<br />
ISDN<br />
GSM<br />
T AL K / D AT A<br />
T AL K R S C S T R R D T D C D PSTN<br />
Im Maximalausbau ermöglicht der skalierbare EDW.collector die Ablesung von bis zu<br />
30 Mio. Haushaltskunden und 3 Mio. Lastgangzählern online (Foto: GÖRLITZ)<br />
One or more „Command Control<br />
Servers“ perform the management<br />
of reading schedules and distribute<br />
reading jobs to the individual<br />
collection machines. This server<br />
level can consist of 1-n machines,<br />
depending on the required overall<br />
performance.<br />
Comservers and<br />
open meter engines<br />
The second level is the “reading<br />
machines”. They are not limited by<br />
number and can be separated <strong>with</strong><br />
firewalls or DMZ from the main<br />
network. The EDW.collector´s<br />
comservers support GSM, GPRS,<br />
analogue and digital PSTN, ISDN,<br />
Powerline, and TCP/IP-based network<br />
connections.<br />
The third system level is „data<br />
translation servers“ where the<br />
raw data from <strong>meters</strong> is analysed<br />
and separated into measurement<br />
data, status information, and load<br />
profile data. A new feature is the<br />
standardisation of meter-specific<br />
para<strong>meters</strong> in the software system.<br />
All meter-related program parts<br />
are encapsulated in separate<br />
OME drivers. These drivers can be<br />
installed into the main system at<br />
any time and <strong>with</strong>out the need to<br />
adapt or upgrade the main system<br />
installation.<br />
OME drivers contain information<br />
1 ... n<br />
Datenbank<br />
Datenbank<br />
on the data protocol of the meter,<br />
the communication media used,<br />
instructions for data interpretation,<br />
and device parametrisation, as<br />
well as screen design information<br />
for the EDW3000 meter device<br />
screen.<br />
Writing drivers is not limited to<br />
GÖRLITZ staff only - anyone<br />
interested can receive the driver<br />
specification and can create<br />
their own drivers for their meter<br />
equipment. This open handling is<br />
very important for future software<br />
integration as even standardised<br />
DLMS <strong>meters</strong> vary so considerably<br />
that the ENZ2000 already recognises<br />
7 different DLMS drivers.<br />
Standardised interconnectivity<br />
The individual modules of the<br />
EDW.collector can run on a single<br />
PC or can be distributed to an<br />
unlimited number of servers – if<br />
a higher performance is required.<br />
The communication between the<br />
EDW.collector’s modules is carried<br />
out using the new Microsoft Messaging-Queue<br />
standard (MSQS).<br />
MSQS is a scalable application<br />
connectivity system that is capable<br />
of managing data exchange in high<br />
volumes and operates on Windows<br />
2000/2003 and Windows XP. The<br />
first version of the EDW.collector<br />
will be released in February next<br />
year, followed by individual driver<br />
development.