EDW.collector<br />

LAN / WAN<br />

ling and monitoring was used as<br />

the core building blocks for the<br />

EDW3000.<br />

DataTranslationServer<br />

DTS<br />

CommandControlServer<br />

CCS<br />

From the ENZ2000<br />

to the EDW3000<br />

This system serves as the platform<br />

for the EDW.collector meter<br />

reading system. The new system<br />

has several new functionalities<br />

that were lacking in the previous<br />

ENZ2000 and it is also compliant<br />

<strong>with</strong> tomorrow’s IT architecture.<br />

The second project step was to<br />

integrate the old data retrieval<br />

software ENZ into the new database<br />

platform EDW, using the<br />

EDW.command development.<br />

Any “old” ENZ2000 can now be<br />

controlled and monitored <strong>with</strong><br />

a “new” EDW3000 system. This<br />

was the prerequisite to enable a<br />

seamless switch from the old to<br />

the new system environment.<br />

T A L K / D AT A<br />

T AL K<br />

ComServer<br />

Flexible resource<br />

management<br />

The third and current project step<br />

is the development and completion<br />

of the new data collection<br />

module EDW.collector to complete<br />

the whole migration process. The<br />

architecture of the new collector is<br />

more flexible in terms of installation<br />

and performance configuration<br />

compared <strong>with</strong> the ENZ2000.<br />

Im Minimalausbau des Systems können<br />

Modemsteuerung, Datenbank und Client<br />

auf einem einzigen PC installiert werden (Foto: GÖRLITZ)<br />

R S C S T R R D T D C D<br />

ISDN<br />

GSM<br />

EDW.engine<br />

EDW.client<br />

Datenbank<br />

T AL K / D A T A<br />

T A L K<br />

R S C S T R R D T D C D<br />

PSTN<br />

1 ... n<br />

DataTranslationServer<br />

DTS<br />

1 .. n<br />

EDW.client(s)<br />

1 ... n<br />

CommandControlServer<br />

CCS<br />

11/2004 METERING automation 27<br />

LAN<br />

1 .. n<br />

EDW.engine<br />

1 ... n<br />

ComServer<br />

T AL K / D AT A<br />

T AL K<br />

R S C S T R R D T D C D<br />

LAN /<br />

WAN<br />

ISDN<br />

GSM<br />

T AL K / D AT A<br />

T AL K R S C S T R R D T D C D PSTN<br />

Im Maximalausbau ermöglicht der skalierbare EDW.collector die Ablesung von bis zu<br />

30 Mio. Haushaltskunden und 3 Mio. Lastgangzählern online (Foto: GÖRLITZ)<br />

One or more „Command Control<br />

Servers“ perform the management<br />

of reading schedules and distribute<br />

reading jobs to the individual<br />

collection machines. This server<br />

level can consist of 1-n machines,<br />

depending on the required overall<br />

performance.<br />

Comservers and<br />

open meter engines<br />

The second level is the “reading<br />

machines”. They are not limited by<br />

number and can be separated <strong>with</strong><br />

firewalls or DMZ from the main<br />

network. The EDW.collector´s<br />

comservers support GSM, GPRS,<br />

analogue and digital PSTN, ISDN,<br />

Powerline, and TCP/IP-based network<br />

connections.<br />

The third system level is „data<br />

translation servers“ where the<br />

raw data from <strong>meters</strong> is analysed<br />

and separated into measurement<br />

data, status information, and load<br />

profile data. A new feature is the<br />

standardisation of meter-specific<br />

para<strong>meters</strong> in the software system.<br />

All meter-related program parts<br />

are encapsulated in separate<br />

OME drivers. These drivers can be<br />

installed into the main system at<br />

any time and <strong>with</strong>out the need to<br />

adapt or upgrade the main system<br />

installation.<br />

OME drivers contain information<br />

1 ... n<br />

Datenbank<br />

Datenbank<br />

on the data protocol of the meter,<br />

the communication media used,<br />

instructions for data interpretation,<br />

and device parametrisation, as<br />

well as screen design information<br />

for the EDW3000 meter device<br />

screen.<br />

Writing drivers is not limited to<br />

GÖRLITZ staff only - anyone<br />

interested can receive the driver<br />

specification and can create<br />

their own drivers for their meter<br />

equipment. This open handling is<br />

very important for future software<br />

integration as even standardised<br />

DLMS <strong>meters</strong> vary so considerably<br />

that the ENZ2000 already recognises<br />

7 different DLMS drivers.<br />

Standardised interconnectivity<br />

The individual modules of the<br />

EDW.collector can run on a single<br />

PC or can be distributed to an<br />

unlimited number of servers – if<br />

a higher performance is required.<br />

The communication between the<br />

EDW.collector’s modules is carried<br />

out using the new Microsoft Messaging-Queue<br />

standard (MSQS).<br />

MSQS is a scalable application<br />

connectivity system that is capable<br />

of managing data exchange in high<br />

volumes and operates on Windows<br />

2000/2003 and Windows XP. The<br />

first version of the EDW.collector<br />

will be released in February next<br />

year, followed by individual driver<br />

development.