<strong>EAD</strong> <strong>200wi</strong><br />

2.9 Configuration of DIP switches for the ISDN bus termination resistors<br />

For a correct termination of ISDN S bus the <strong>EAD</strong> <strong>200wi</strong> is equipped with<br />

internal termination resistors (TR). Depending on the installed bus system,<br />

the correct resistance can be set with DIP switches. The switches are<br />

located rightmost in the connection area. The switch pairs SW1 + SW2<br />

and SW3 + SW4 are each connected in parallel, so that these combinations can be set: 100 Ω,<br />

50 Ω or No Parallel Resistor. Default setting is 100 Ω valid for short passive bus and extended<br />

bus. For Y configuration termination resistors have to be switched off. 50 Ω is a special setting,<br />

please do not set it. If the switch setting has been changed, it is always necessary to perform<br />

a restart (see chapter 2.7).<br />

Figure 7: ISDN bus systems<br />

Version: 2012/06/06 27<br />

100 Ohm<br />

50 Ohm<br />

Termination resistors<br />

switched off<br />

1 2 3 4<br />

1 2 3 4<br />

1 2 3 4<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

Default<br />

setting