EN<br />

...with the appliance itself<br />

<strong>DW12</strong>-<strong>TFE1</strong>/ <strong>TFE2</strong> Series<br />

Error displays on the Stop light “ A ”with it blinking all the time.<br />

When the buzzer emits 1 short warning signal every 30 seconds.<br />

Have you checked whether:<br />

the door is closed properly.<br />

When the buzzer emits 3 short warning signal every 30 seconds.<br />

Have you checked whether:<br />

the drain hose is too low.<br />

When the buzzer emits 4 short warning signal every 30 seconds.<br />

Have you checked whether:<br />

the drain hose is crimped or bent.<br />

the drain hose is too high.<br />

When the buzzer emits 5 short warning signal every 30 seconds.<br />

Have you checked whether:<br />

the water is turned on and the hose is connected properly;<br />

the water supply to the house is on and has sufficient pressure;<br />

the water supply hose is crimped or bent;<br />

the filter for the water supply hose is clogged.<br />

the drain hose is too low.<br />

<strong>DW12</strong>-<strong>TFE2</strong> Series<br />

A<br />

B<br />

C<br />

D<br />

H<br />

I<br />

<strong>DW12</strong>-<strong>TFE1</strong> Series<br />

A<br />

B<br />

When the buzzer emits 2 or 6 short warning signals every 30 seconds,Contact the nearest<br />

authorized service center.<br />

<strong>DW12</strong>-<strong>TFE3</strong> Series<br />

Error display on the time-remaining indicator<br />

When the buzzer emits 10 short warning signal every 30 seconds and the time-remaining indicator<br />

display "E1"<br />

Have you checked whether:<br />

the door is closed properly.<br />

21<br />

When the buzzer emits 10 short warning signal every 30 seconds and the time-remaining indicator<br />

display "E3"<br />

Have you checked whether:<br />

the drain hose is too low.