In the final report of work package 2 a further investigation of the collective of interven-<br />

tional cardiologists and radiologists and of flight crew members was therefore recom-<br />

mended. The results of work package 2 were discussed in detail with BfS. As a result the<br />

BfS commissioned the further piloting of both collectives.<br />

6.3 Results of work package 3<br />

An epidemiological study is feasible in principle in both investigated collectives.<br />

- Taking into account the expected participation rates, both collectives are large enough<br />

to detect a difference in prevalence of 23 % to 10 % (as seen in the first few studies on<br />

interventionally acting doctors (Ciraj-Bjelac et al. 2010b)) with a statistical power of<br />

80%.<br />

- For both collectives, a non-exposed comparison collective can be recruited among their<br />

colleagues.<br />

- The collectives are homogenous concerning many factors so that even internal compari-<br />

sons have a high validity.<br />

- For both collectives the registration of risk factors and potential confo<strong>und</strong>ers can be<br />

carried out in the same way and in a fashion comparable to former studies by using<br />

questionnaires.<br />

- Radiation exposure of the lens during work can be reconstructed, even historically, in<br />

both cases. The registration of necessary data can be donepreparative. For the estimation<br />

of radiation doses it is useful to include the results of current research of the EU-<br />

fo<strong>und</strong>ed project ORAMED (Carinou et al. 2011; Domienik et al. 2011; Gualdrini et al.<br />

2011) and of ICRP (update of Volume 74 (Petoussi-Henß 2011)). For interventional<br />

cardiologists and radiologists, a validation of dose estimation using measurementswith<br />

thermoluminescence dosemeters in cooperation with the ORAMED research group is<br />

highly desirable.<br />

- Lens opacities can be objectively documented in a standardised way and classified with<br />

reliable procedures. A comparability with some international studies (among others<br />

those of atom bomb survivors (Jacob et al. 2010b; Mrena et al. 2011; Neriishi et al.<br />

2007)) is therefore feasible.<br />