After aligning the air-termination rod/air-termination tip, the aluminium roof tile must be fitted in<br />

place as follows:<br />

1. Before installing the aluminium roof tile, check the surfaces of the adjoining roof tiles to which<br />

the aluminium tile is to be adhered. These surfaces must be clean, dry as well as free of dust,<br />

grease and moss. Observe a temperature range of +5°C to +40°C!<br />

2. Position the air-termination rod/air-termination tip in the centre of the roofing so that the<br />

aluminium roof tile completely covers the original roof tile over the entire surface.<br />

The air-termination rod/air-termination tip must not contact any point of the hole in the<br />

aluminium roof tile. No pressure or stress must be applied to the aluminium roof tile. Compared<br />

with a lead tile (which is only loosely installed (“floating”)), the aluminium roof tile is firmly<br />

attached to the roof by butyl adhesive strips.<br />

Due to its centred position, the air-termination rod/air-termination tip has enough space for<br />

“swinging”. If this space is not provided, the aluminium roof tile may become leaky in the<br />

course of time (see Fig. 9 and 10, page 12).<br />

centred position<br />

Fig. 9<br />

correct<br />

bottom position<br />

3. Remove the three adhesive protection strips from the aluminium roof tile and firmly press it on<br />

the adjoining roof tiles. The adhesive on the aluminium roof tile is vulcanised by solar radiation<br />

and will gradually harden (see Fig. 10 and Fig. 11, page 12).<br />

Note:<br />

If the surface to which the aluminium roof tile is adhered is not clean enough, the adhesive<br />

strips will not properly stick to the surface. In this case, it is advisable to use replacement<br />

adhesive strips.<br />

The aluminium roof tile must be flanged underneath the roof tiles situated above to ensure that<br />

rain water (driving rain) does not to penetrate underneath the roofing.<br />

Moreover, the aluminium roof tile must overlap the roof tile on the right side and the roof tiles<br />

underneath it.<br />

The aluminium roof tile must be flanged to these roof tiles in a plane way (see Fig. 10 and<br />

Fig. 11, page 12).<br />

11<br />

incorrect top position<br />

incorrect