28<br />
5 Curing<br />
5.2 Start Exposure Time<br />
There are 2 possibilities for starting the exposure time available.<br />
Starting via Button START or Footswitch<br />
Time Controlled Mode:<br />
To start the exposure time push button START or press footswitch. The concurrent time<br />
is displayed in the main window TIME. The exposure cycle stops when time is run off.<br />
Continuous Mode:<br />
The length of the start signal defines the length of the exposure time. It lasts as long as<br />
the footswitch or the START button is pressed.<br />
Starting via a Higher Ranking Controller<br />
Via the interface XS2 starting of an exposure cycle is also possible.<br />
The length of the exposure time is defined by the length of the start signal and is<br />
controlled by the higher-ranking controller.<br />
5.3 Working with the Light Guide<br />
• Position the light guide so that the light cone is directed to the adhesive. The distance<br />
should be no closer than approximately 6-8 mm (appr. 0.25 inch) to prevent vapors<br />
from accumulating on the wand. Distance and exposure time should initially be<br />
monitored to be sure that the adhesive or substrate is not overheated or discoloration<br />
will happen.<br />
5.4 PLC Interface<br />
The unit is equipped with an interface for computer-controlled systems. This interface<br />
permits you to control and monitor six important system parameters via Programmable<br />
Logic Control units. The interface is galvanically isolated from the power supply by optocouplers<br />
only for incoming signals, and is read out by means of the external voltage<br />
supplied by the PLC unit only. Outgoing signals are controlled via relais (24 VDC,<br />
200 mA), see Section 9.2.<br />
The following functions are available:<br />
– Action (Input signal):<br />
Timer start in time mode<br />
Shutter open in continuous mode<br />
– Signal (Output signal):<br />
System overheated<br />
Lamp ready / full power<br />
Shutter open<br />
Ignition successful<br />
UV minimum reached