28<br />

5 Curing<br />

5.2 Start Exposure Time<br />

There are 2 possibilities for starting the exposure time available.<br />

Starting via Button START or Footswitch<br />

Time Controlled Mode:<br />

To start the exposure time push button START or press footswitch. The concurrent time<br />

is displayed in the main window TIME. The exposure cycle stops when time is run off.<br />

Continuous Mode:<br />

The length of the start signal defines the length of the exposure time. It lasts as long as<br />

the footswitch or the START button is pressed.<br />

Starting via a Higher Ranking Controller<br />

Via the interface XS2 starting of an exposure cycle is also possible.<br />

The length of the exposure time is defined by the length of the start signal and is<br />

controlled by the higher-ranking controller.<br />

5.3 Working with the Light Guide<br />

• Position the light guide so that the light cone is directed to the adhesive. The distance<br />

should be no closer than approximately 6-8 mm (appr. 0.25 inch) to prevent vapors<br />

from accumulating on the wand. Distance and exposure time should initially be<br />

monitored to be sure that the adhesive or substrate is not overheated or discoloration<br />

will happen.<br />

5.4 PLC Interface<br />

The unit is equipped with an interface for computer-controlled systems. This interface<br />

permits you to control and monitor six important system parameters via Programmable<br />

Logic Control units. The interface is galvanically isolated from the power supply by optocouplers<br />

only for incoming signals, and is read out by means of the external voltage<br />

supplied by the PLC unit only. Outgoing signals are controlled via relais (24 VDC,<br />

200 mA), see Section 9.2.<br />

The following functions are available:<br />

– Action (Input signal):<br />

Timer start in time mode<br />

Shutter open in continuous mode<br />

– Signal (Output signal):<br />

System overheated<br />

Lamp ready / full power<br />

Shutter open<br />

Ignition successful<br />

UV minimum reached