3. OPERATION<br />
3.1 USING THE OPERATION KEYS OF THE CONTROL PANEL<br />
Programming is carried out via 4 keys<br />
OK key: is used to confirm the entry and to enter the<br />
administration menu.<br />
< and > -keys: to <strong>ch</strong>ange the digits in the display and to<br />
navigate within the menu<br />
(refer to <strong>ch</strong>apter 3.3).<br />
ESC key (X): To cancel the current entry.<br />
PROGRAM, MENU FUNCTIONS AND DISPLAY<br />
Normal operation (blinking dot) .<br />
Enroll user (enroll user) Eu<br />
Delete user (delete user) du<br />
Set security code (Security code) Sc<br />
Reset to initial settings rr<br />
(to delete all settings and data)<br />
3.2 INITIAL START-UP: COUPLING SCANNER AND CONTROL PANEL<br />
When the devices are initially connected to the power supply, the display of the control<br />
panel begins counting backwards until connection has been established with the scanner.<br />
Two red dots are then displayed. During this time the LED light remains red. After<br />
booting is completed, the LED light begins to blink orange. The device can now be<br />
initialised.<br />
Press the OK button and then the ESC button. “EF” (i.e. enrol finger) appears on the<br />
display of the control panel. If a previously recorded finger is drawn over the sensor, the<br />
initialisation process is started without losing existing data. In case no fingers have been<br />
enrolled yet (new installation), press the ESC key to finalize the initialisation process.<br />
Initialisation is carried out fully automatic. The devices are coupled with ea<strong>ch</strong> other to<br />
prevent tampering of the scanner and unauthorised access. The blinking decimal point in<br />
the scanner panel signals normal operation after the initialisation process has been<br />
completed. The security code is set to a default value of 99. Please <strong>ch</strong>ange this code as<br />
soon as possible to a security code of your own <strong>ch</strong>oice.<br />