2.9 System parameters: Communication

2.9.1 External communication error

7520 External communication error (with option H2 or H3)

No. Setting Range Factory

setting

Description

7521 Ext. comm.

error

7522 Ext. comm.

error

7523 Ext. comm.

error

Delay 1.0 to 100.0 s 10.0 s Supervision of the external

communication line. The alarm

Relay output A

Relay output B

Not used (option

dependent)

Not used (option

dependent)

Not used

Not used

will occur when there has been

no communication during the

delay time.

7524

Ext. comm.

error

Enable

OFF

ON

OFF

7525

Ext. comm.

error

Fail class F1 to F9 F2 (Warning)

7530 Internal communication ID

No. Setting Range Factory

setting

7532 Int. comm. ID CAN fail. mode Manual

Semi auto

No mode change

Manual

7533 Int. comm. ID Missing all units F1 to F9 F2 (Warning)

7534 Int. comm. ID Fatal CAN error F1 to F9 F2 (Warning)

7535 Int. comm. ID Any DG missing F1 to F9 F2 (Warning)

7536 Int. comm. ID Any mains missing F1 to F9 F2 (Warning)

Description

The mode decides the reaction

of the power management

system in case of different

errors on the CAN

communication lines.

Mode:

• Manual

• Semi auto

• No mode change

2.9.2 Engine interface communication alarms

7570 EI comm. error (with option H5, H7, H12, or option H6)

No. Setting Range Factory

setting

Description

7571 EI comm.

error

7572 EI comm.

error

7573 EI comm.

error

Timer 0.0 to 100.0 s 0.0 s Supervision of the EIC

communication line. The alarm

Relay output A

Relay output B

Not used (option

dependent)

Not used (option

dependent)

Not used

Not used

will occur when there has been

no communication during the

delay time.

7574 EI comm.

error

Enable

OFF

ON

ON

7575

EI comm.

error

Fail class F1 to F9 F2 (Warning)

PARAMETER LIST 4189340688R EN Page 121 of 222