Operational faults<br />

Be<strong>for</strong>e each fault elimination:<br />

− Switch off device.<br />

− Wait <strong>for</strong> standstill of the device.<br />

− Pull out mains plug.<br />

Fault Possible cause Remedy<br />

Motor does not start<br />

Motor hums but does not start<br />

Shredding material is not drawn<br />

into the shredder<br />

No power supply Check fuses<br />

Mains cable defective have these checked (electrician)<br />

Machine overloaded/blocked and automatically<br />

cuts out after 5 seconds reversing.<br />

Retaining basket unlocked<br />

(safety cut-out device of the retaining<br />

basket has tripped)<br />

Blade shaft blocked even after several<br />

reversing tries.<br />

To restart press the infeed switch<br />

Lock the retaining basket<br />

1. Loosen the adjusting knob (J).<br />

2. Press the reversing switch .<br />

Capacitor faulty Bring machine to manufacturer or authorised workshop<br />

<strong>for</strong> repair<br />

The cutting roller is running in reverse.<br />

Wrong switch position<br />

Shredding material caught in funnel<br />

Switch off device and switch over direction of rotation<br />

selector switch.<br />

Press the infeed switch .<br />

Shredding material too soft or wet Push down with a branch and shred<br />

Cutting roller worn Adjust fixed counter blade as described under „adjusting<br />

the fixed counter blade“. In case of severe<br />

wear, replace cutting roller.<br />

Shredding material not cut cleanly. Fixed counter blade not adequately<br />

adjusted.<br />

Device starts but blocks under as<br />

slight load and switches off via<br />

protective motor switch.<br />

Extension cable too long or crosssection<br />

to small.<br />

Socket too far from mains supply and<br />

cross-section of mains cable too small.<br />

Adjust fixed counter blade.<br />

Extension cable at least 1.5 mm², maximum 25 m<br />

long. If a longer cable is used, minimum crosssection<br />

2.5 mm².<br />