Elma 811 + 817 + 515 side 71To recall, switch on the meter, then press the start, up, or down arrow button momentarily to“CALL” the logged data. The LCD annunciator “C” will be flashing to indicate that you arereviewing logged data on screen. The logged data can also be downloaded to a PC through theRS232C support in the meter with the additional BR51X PC interface kit.When in pause mode “H” or call mode “C”, the following on screen data item review features canquickly help you outline the key points of your logged data without the help of a computer:1) Press the up (or down) arrow button momentarily to step through the logged data.2) Press and hold the up (or down) arrow button to quickly scan the logged data; the beeper willbeep continuously when the first or the last data is reached.3) Press simultaneously the up and down arrow buttons momentarily to alternately display themaximum and minimum readings of the logged data.
Elma 811 + 817 + 515 side 724) Press the up (or down) arrow button momentarily while press-and-hold the HOLD button tosearch through the turning points (max, min, max, min, …etc) of the logged data. The LCDannunciator “MAX” or “MIN” will be flashing to indicate a downward or upward turning point.Press the “timer” button momentarily to display the selected sampling speed in the unit of seconds.Factory default t0.05 means sampling speed is 0.05 second. Press the up (or down) arrow buttonmomentarily to select a different sampling speed from 0.05s (0.2s for O C/ O F & Ω, 0.4s for Hz, and1s for Cx), 1s, 20s, 40s, 60s, 120s, 240s, up to the slowest 480s. Then press the “timer” buttonmomentarily again to confirm the new setting.Note:1) The timer cannot be set while data logging is running. Please set the timer before starting datalogging, or pause data logging if you want to alter the timer setting during data logging.2) When a sampling speed of 20s or longer is selected, approximately 4.5 minutes after data loggingis started, the meter will enter an intelligent Sleep-and-Log standby mode between data loggingmeasurements. Only a swinging bar chart pointer will be displayed in the LCD. The meter powerconsump tion will be decreased to approx. 1/30 of the normal mode. Press the SELECT buttonmomentarily can wake up the meter to see real time measurements again.
- Page 21 and 22: Elma 811 + 817 + 515 side 20Batteri
- Page 23 and 24: Elma 811 + 817 + 515 side 22Innehå
- Page 25 and 26: Elma 811 + 817 + 515 side 241.2 Ord
- Page 27 and 28: Elma 811 + 817 + 515 side 263 Instr
- Page 29 and 30: Elma 811 + 817 + 515 side 283.5 NMR
- Page 31 and 32: Elma 811 + 817 + 515 side 304.3 Tem
- Page 33 and 34: Elma 811 + 817 + 515 side 324.5 Aut
- Page 35 and 36: Elma 811 + 817 + 515 side 344.7 RS
- Page 37 and 38: Elma 811 + 817 + 515 side 364.11 Ho
- Page 39 and 40: Elma 811 + 817 + 515 side 384.15 St
- Page 41 and 42: Elma 811 + 817 + 515 side 40Bedienu
- Page 43 and 44: Elma 811 + 817 + 515 side 42• Bei
- Page 45 and 46: Elma 811 + 817 + 515 side 44Analog-
- Page 47 and 48: Elma 811 + 817 + 515 side 46Kapazit
- Page 49 and 50: Elma 811 + 817 + 515 side 48ΩWider
- Page 51 and 52: Elma 811 + 817 + 515 side 50µA-, m
- Page 53 and 54: Elma 811 + 817 + 515 side 52Hinterg
- Page 55 and 56: Elma 811 + 817 + 515 side 54Ausscha
- Page 57 and 58: Elma 811 + 817 + 515 side 56USER'S
- Page 59 and 60: Elma 811 + 817 + 515 side 58Measure
- Page 61 and 62: Elma 811 + 817 + 515 side 60Analog
- Page 63 and 64: Elma 811 + 817 + 515 side 62Capacit
- Page 65 and 66: Elma 811 + 817 + 515 side 64Ω Resi
- Page 67 and 68: Elma 811 + 817 + 515 side 66μA, mA
- Page 69 and 70: Elma 811 + 817 + 515 side 68Backlit
- Page 71: Elma 811 + 817 + 515 side 70Data lo
- Page 75 and 76: Elma 811 + 817 + 515 side 74Battery
- Page 77 and 78: Elma 811 + 817 + 515 side 76Safety:
- Page 79 and 80: Elma 811 + 817 + 515 side 78AC Curr
<strong>Elma</strong> 811 + 817 + 515 side 724) Press the up (or down) arrow button momentarily while press-and-hold the HOLD button tosearch through the turning points (max, min, max, min, …etc) of the logged data. The LCDannunciator “MAX” or “MIN” will be flashing to indicate a downward or upward turning point.Press the “timer” button momentarily to display the selected sampling speed in the unit of seconds.Factory default t0.05 means sampling speed is 0.05 second. Press the up (or down) arrow buttonmomentarily to select a different sampling speed from 0.05s (0.2s for O C/ O F & Ω, 0.4s for Hz, and1s for Cx), 1s, 20s, 40s, 60s, 120s, 240s, up to the slowest 480s. Then press the “timer” buttonmomentarily again to confirm the new setting.Note:1) The timer cannot be set while data logging is running. Please set the timer before starting datalogging, or pause data logging if you want to alter the timer setting during data logging.2) When a sampling speed of 20s or longer is selected, approximately 4.5 minutes after data loggingis started, the meter will enter an intelligent Sleep-and-Log standby mode between data loggingmeasurements. Only a swinging bar chart pointer will be displayed in the LCD. The meter powerconsump tion will be decreased to approx. 1/30 of the normal mode. Press the SELECT buttonmomentarily can wake up the meter to see real time measurements again.