Projekt:<br />
Mini-elevator<br />
Klient:<br />
SBS Byfornyelse<br />
4.6.24 Med altan: a=2,6 m, b=2,8 m<br />
Steel temperature - a=2.6 m,b=2.8 m<br />
Temperature [°C]<br />
220<br />
200<br />
180<br />
160<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
z=1 m<br />
z=2 m<br />
z=3 m<br />
z=4 m<br />
z=5 m<br />
z=6 m<br />
20<br />
0 500 1000 1500 2000 2500 3000 3500 4000<br />
Time [s]<br />
Figur 50: GRØN/konstruktion 6 - med altan: a=2,6 m, b=2,8 m – T ~ 210°<br />
C<br />
max<br />
6 Kun temperaturene for punkter nærmest window plume er angivet.<br />
Brandteknisk analyse af 01-10-05:<br />
me_bta_udg_MBM_051001_1.doc<br />
- 42 -<br />
<strong>Safety</strong>