<strong>HWAM</strong> <strong>Monet</strong><br />
Installation af vandtank • Installation of boiler<br />
Installation von Wassertank • Bruksanvisning
Indholdsfortegnelse, dansk<br />
Sikkerhedsmæssige lovkrav ................................................................................................................. 5<br />
Tilslutning til centralvarmeanlæg .......................................................................................................... 6<br />
Totalopvarmning ................................................................................................................................... 7<br />
Tilslutning til solfangeranlæg ................................................................................................................ 8<br />
Tilslutning sammen med jordvarmeanlæg ............................................................................................ 9<br />
Tilslutning med automatisk virkende AVTA-ventil ............................................................................... 10<br />
Overensstemmelseserklæring ............................................................................................................ 11<br />
Table of content, English<br />
Instructions for connection of a stove with domestic water heating .................................................... 14<br />
Connection to central heating system ................................................................................................ 15<br />
Total heating ....................................................................................................................................... 16<br />
Connection to solar collector system .................................................................................................. 17<br />
Connection with geothermal energy system ...................................................................................... 18<br />
Connection with automatically functioning AVTA valve ....................................................................... 19<br />
Inhaltsverzeichnis, Deutsch<br />
Vorschriften für den Anschluss eines Ofens mit Brauchwasser-Erwärmung ...................................... 21<br />
Anschluss an eine Zentralheizungsanlage ......................................................................................... 22<br />
Alleinheizung ...................................................................................................................................... 23<br />
Anschluss mit Erdwärme-Kollektoranlage .......................................................................................... 24<br />
Anschluss an Sonnenkollektoranlage ................................................................................................. 25<br />
Anschluss mit Thermosicherung und geschlossener Expansion ....................................................... 27<br />
Innehållsförteckning, svensk<br />
Säkerhetsmässiga krav enligt lagen ................................................................................................... 28<br />
Anslutning till centralvärmeanläggning ............................................................................................... 29<br />
Totaluppvärmning ............................................................................................................................... 30<br />
Anslutning till solfångaranläggning ..................................................................................................... 31<br />
Anslutning till jordvärmeanläggning .................................................................................................... 32<br />
Anslutning till automatiskt verkande AVTA-ventil ................................................................................ 33
Sikkerhedsmæssige lovkrav<br />
Tilslutning af vandtank skal ske i henhold til Arbejdstilsynets publikation nr. 42 "Forskrifter for<br />
fyrede varmtvandsanlæg". Heri henvises specielt til afsnit 2 om blandt andet sikkerhedsledning<br />
til åben ekspansionsbeholder. Sikkerhedsledningen skal sikre, at ovnens kedel kan komme af<br />
med trykket, hvis den på grund af manglende gennemstrømning (for eksempel ved strømsvigt)<br />
skulle komme i kog.<br />
Hvis vandet i tanken/kedlen koger, vil vandet blive trykket ud gennem sikkerhedsledningen<br />
til den åbne ekspansionsbeholder. Ekspansionsbeholderen skal derfor afsluttes ved gulv og<br />
afløb, så der ikke kan ske vandskade. Ekspansionsbeholderen skal dimensioneres, så den kan<br />
optage udvidelsen af anlæggets vand, når det opvarmes fra 0°C til 100°C. I praksis 4-8%.<br />
Ekspansionsbeholderen og sikkerhedsledningen skal være frostsikret.<br />
Dansk<br />
Ekspansionsbeholderens vandstand skal jævnligt kontrolleres. Efter udluftning af anlægget,<br />
eller hvis der er kogt vand ud gennem ekspansionsbeholderens overløb, skal vandstanden<br />
kontrolleres og eventuelt efterfyldes.<br />
1. <strong>HWAM</strong> <strong>Monet</strong> brændeovn med vandkedel.<br />
2. Afgangsstuds (øverst 1").<br />
3. Sikkerhedsledning, mindste indvendige<br />
diameter for stålrør: 21,6 mm, for kobberrør:<br />
19,5 mm.<br />
Max. længde: 20 m, max. højde: 10 m.<br />
Sikkerhedsledningen må ikke kunne<br />
afspærres.<br />
4. Åben ekspansionsbeholder. Skal kunne<br />
rumme op til 8% af anlæggets samlede<br />
vandindhold.<br />
5. Ø 15 mm hævertbryder.<br />
6. Meldeledning og overløb. Føres til gulv og<br />
skal være skråt afskåret.<br />
7. Gulvafløb.<br />
8. Påfyldnings- og aftapningshane.<br />
9. Fremløb<br />
10. Retur.<br />
11. Automatisk luftudlader.<br />
T. Termometer, skal kunne måle op til 120°<br />
C<br />
M. Manometer med rød markering ved højeste<br />
vandsøjle. T + M kan være kombineret.
Sikkerhedsledningen, som samtidig kan være returledningen til centralfyret, skal udgå fra<br />
ovnens topstuds. <strong>HWAM</strong> <strong>Monet</strong>'s hedeflade udgør 0,28 m og må derfor tilsluttes med dykket<br />
sikkerhedsledning. Der skal så blot på det højeste punkt efter afgangsstudsen monteres en<br />
automatisk luftudlader (11).<br />
Tilslutning til centralvarmeanlæg<br />
<strong>HWAM</strong> <strong>Monet</strong> kan tilsluttes et nyt eller indkobles på et eksisterende centralvarmeanlæg som<br />
en supplerende hjælpekedel. Fremløbsvandet skal tilsluttes ved 4, og afgangsvandet fra<br />
brændeovnen skal tilsluttes anlæggets returlinie. En del af fremløbsvandet vil så cirkulere gennem<br />
ovnen, hvor det varmes yderligere op, inden det blandes med det koldere returvand.<br />
Samtidig sikres det, at der altid er gennemstrømning i ovnen, uanset om varmeanlæggets<br />
radiatortermostater skulle være lukkede.<br />
Afhængig af varmebehovet kan shuntventilen stilles på "sommerstilling" for hurtig udnyttelse<br />
af ovnen til opvarmning af andre rum med radiatorer. Er varmebehovet ikke særligt stort, kan<br />
det blive nødvendigt at sætte shunten over mod "vinterstilling" for at inddrage mere vand i<br />
cirkulationen. Med shunten i "vinterstilling" opvarmes brugsvand med kedlen.<br />
<strong>HWAM</strong> <strong>Monet</strong> tilsluttet et centralvarmeanlæg<br />
1. <strong>HWAM</strong> <strong>Monet</strong><br />
2. Udluftning<br />
3. Afgang<br />
4. Tilgang med AVTA-ventil<br />
5. Gulvvarme<br />
6. Radiator<br />
7. Fremløb<br />
8. Retur<br />
9. Retur- og sikkerhedsledning<br />
10. Oliefyr<br />
11. Varmt vand<br />
12. Åben ekspansionsbeholder<br />
13. Shuntventil<br />
14. Pumpe
Totalopvarmning<br />
Principskitse for totalopvarmning<br />
<strong>HWAM</strong><br />
<strong>Monet</strong><br />
Åben<br />
ekspansionsbeholder<br />
Brændeovnskreds<br />
Varmtvandsbeholder<br />
Radiatorkreds<br />
Afgang varmt vand<br />
El-stav<br />
Tilgang koldt vand<br />
Radiator Pumpe<br />
T: Termostat KP77<br />
M1: AT mix-ventil<br />
VT: Termostatventil<br />
Gulvvarmekreds<br />
Gulvvarme<br />
Brugsvand og rumopvarmning<br />
<strong>HWAM</strong> <strong>Monet</strong> kan tilsluttes en automatisk virkende mix-ventil og en KP77 termostat til at<br />
starte pumperne. Anlægget prioriterer først det varme brugsvand. Derefter inddrages radiatorkredsen<br />
til rumopvarmning. Ovnens konvektionssystem afgiver dog hurtigt varme til<br />
rummet. Bedst virkning får man, hvis overskudsvarmen veksles over til gulvvarme. Gulvene<br />
virker som et varmelager, der langsomt afgiver varmen til rummene. Mix-ventilen sikrer, at<br />
vandtanken i <strong>HWAM</strong> <strong>Monet</strong> altid er over 50°C. Dette giver en bedre forbrænding og dermed<br />
en højere virkningsgrad.<br />
Funktion<br />
Når der tændes op i brændeovnen, registrerer termostaten (T), som har en føler (F3) i ovnens<br />
afgangsstuds, en højere temperatur (over 60°C) og starter cirkulationspumpen. Vekslerspiralen<br />
i kombibeholderen opvarmer efter kort tids fyring det varme brugsvand. Når returvandet fra<br />
kombibeholderen overstiger mix-ventilens (M1) indstilling, skifter tilgangen efterhånden fra +<br />
over til -. Derved inddrages radiatorkredsen i opvarmningen. Gulvvarmekredsen styres af en<br />
termoventil (VT), som sikrer, at gulvvarmen ikke overophedes.<br />
Når ovnen brænder ud, vil KP77 termostaten slukke pumpen ved 50-55°C. Derved stopper<br />
kredsløbet, inden temperaturen er nede på el-stavens ca. 40°C.<br />
• Anlægget bør frostsikres med termovæske.<br />
• Sikkerhedsledningen fra ovnens afgangsstuds skal altid udføres forskriftsmæssigt og må<br />
ikke kunne afspærres.<br />
• Der skal altid være gennemstrømning på anlægget, så ovnens vandtank kan komme af<br />
med varmen.<br />
• Brændeovnskredsen bør være så lille som mulig og være velisoleret.
Tilslutning til solfangeranlæg<br />
Tilslutning sammen med solfanger<br />
<strong>HWAM</strong> <strong>Monet</strong>, kombineret med et solfangeranlæg på 4-6 m 2 og en ca. 2-300 l kombitank med<br />
ekstra spiral og el-stav, er et særdeles godt alternativ til den traditionelle boligopvarmning<br />
med oliefyr. I sommerperioden klarer solfangeren opvarmningen af brugsvandet. I koldere<br />
perioder, som forår og efterår, suppleres med <strong>HWAM</strong> <strong>Monet</strong>, som giver hurtig konvektionsvarme<br />
til rummet, og supplerer solfangeren ved at opvarme vandet i den øverste halvdel af<br />
kombitanken. I vinterperioden klarer <strong>HWAM</strong> <strong>Monet</strong> hele rumopvarmningen dels ved direkte<br />
konvektionsvarme, og dels via radiator og gulvvarme. Bedst virkning får man, hvis overskudsvarmen<br />
året rundt kan veksles over til gulvvarme. Gulvvarmen virker som et varmelager, der<br />
langsomt afgiver varmen til rummene.<br />
Solfangerkredsens funktion<br />
Ved opvarmning af solfangeren registrerer føleren (F1) en højere temperatur end føleren (F2)<br />
i kombibeholderen, og differenstermostaten (DT) starter cirkulationspumpen. Vekslerkappen<br />
ligger rundt om kombibeholderens nederste ende. Derved udnyttes solfangeren bedst muligt,<br />
også på dage med lille indstråling. Derefter sørger el-staven for den videre opvarmning.<br />
Solfangerkredsen skal af hensyn til frostsikring arbejde med termovæske.<br />
Brændeovnskredsens funktion<br />
Når der tændes op i brændeovnen, registrerer termostaten (F3), som har en føler i ovnens<br />
følerstuds, en højere temperatur (over 60°C) og starter cirkulationspumpen. Vekslerspiralen<br />
i kombibeholderens top opvarmer efter kort tids fyring de øverste 80 l vand. Når returvandet<br />
fra kombibeholderen overstiger mix-ventilens (M1) indstilling, skifter tilgangen efterhånden<br />
fra + over til -. Derved inddrages radiatorkredsen i opvarmningen. Gulvvarmekredsen styres<br />
af en termoventil (VT), som sikrer, at gulvvarmen ikke overophedes.<br />
• Anlægget bør frostsikres med termovæske.<br />
• Sikkerhedsledningen fra ovnens afgangsstuds skal udføres forskriftsmæssigt<br />
og må ikke kunne afspærres.<br />
• Overskudsvarme fra solfangeren kan ikke fordeles ud på radiatorkredsen.<br />
• Brændeovnskredsen bør være så lille som mulig og være velisoleret.<br />
<strong>HWAM</strong> <strong>Monet</strong> tilsluttet sammen med et solfangeranlæg<br />
Ekspansionsbeholder<br />
F3<br />
Pumpe<br />
Brændeovnskreds<br />
220V<br />
T<br />
M1<br />
Kombibeholder<br />
Bypass<br />
Radiatorkreds<br />
Varmt<br />
brugsvand<br />
F1<br />
El-stav<br />
220V<br />
Tryk-<br />
DT<br />
F2<br />
ekspansionsbeholder<br />
Tilgang koldt vand<br />
8<br />
Radiator<br />
Solfangerkreds<br />
Pumpe<br />
Pumpe<br />
VT<br />
Gulvvarme<br />
Gulvvarmekreds<br />
DT: Differenstermostat<br />
M1: AT Mix-ventil<br />
T: Termostat KP 77
Tilslutning sammen med jordvarmeanlæg<br />
<strong>HWAM</strong> <strong>Monet</strong> kobles på normal vis ind på centralvarmeanlægget mellem fremløbs- og<br />
returledningen, således at noget af det varme fremløbsvand opvarmes yderligere, før det<br />
blandes med det kolde returvand. Da varmepumpen ikke tåler varmt returvand, skal der før<br />
varmepumpen indskydes en termostat og en trevejsventil, så det varme returvand cirkulerer<br />
uden om varmepumpen.<br />
Funktion<br />
Når der fyres i ovnen, registrerer termostatens føler stigende temperatur i returledningen,<br />
og trevejsventilen vil lukke vandet uden om varmepumpen og føre det direkte over i fremløbsledningen.Varmepumpen<br />
vil således ikke registrere noget forbrug og vil automatisk koble<br />
ud. Når ovnen brænder ud, vil temperaturen i returledningen falde, og trevejsventilen vil igen<br />
lukke det kolde vand ind i varmepumpen.<br />
<strong>HWAM</strong> <strong>Monet</strong> tilsluttet sammen med jordvarmeanlæg<br />
Varmepumpe<br />
Jordslanger<br />
Motorventil<br />
M<br />
Føler<br />
Termostat<br />
T<br />
Fremløb<br />
9<br />
Ekspansionsbeholder<br />
Afgang<br />
Føler<br />
Tilgang<br />
Sikkerhedsledning<br />
AVTA-ventil<br />
Radiator<br />
Returledning
Tilslutning med automatisk virkende AVTA-ventil<br />
1. Tilgang 3/4" studs.<br />
2. Afgang 1" studs.<br />
3. Følermuffe 3/4"<br />
A. Fremløbsledning.<br />
B. Returledning og ovnens sikkerhedsledning<br />
med forbindelse til<br />
åben ekspansion.<br />
C. AVTA-ventil. Åbner ved stigende<br />
temperatur over 50°C.<br />
Tilslutningen sikrer sammen med en korrekt fyring den optimale udnyttelse af ovnens vandkedel.<br />
Ved at anvende en Danfoss AVTA-ventil 50-90°C kan man sikre en afgangstemperatur fra<br />
ovnens vandbeholder på 70-75°C og derved undgå kondensvand på vandtanken. Samtidig<br />
sikres en bedre efterforbrænding, idet bålet ikke køles for hårdt ned.<br />
AVTA-ventilen monteres på røret til ovnens tilgangsstuds (1) og monteres med føleren gennem<br />
Følermuffen ind i ovnens vandkedel. Ventilen skal monteres ifølge fabrikkens anvisninger.<br />
Såfremt afgangsrøret og sikkerhedsledningen går nedad, bør der altid monteres en automatisk<br />
luftudlader på afgangsrøret. Derved undgås luftlommer, som kan opstå ved overfyring i<br />
optændingsfasen. Føres tilslutningen opad fra ovnen, bør der monteres en aftap-ningshane<br />
på tilgangsstudsen.<br />
Det er forbudt og farligt at blokere sikkerhedsledningen med hane, pumpe eller lignende.<br />
0<br />
D. Automatisk luftudlader.<br />
E. Termometer.<br />
F. Eventuelt manometer.
Overensstemmelseserklæring<br />
Fabrikant:<br />
<strong>HWAM</strong> Heat Design AS<br />
Nydamsvej 53<br />
DK – 8362 Hørning<br />
Tel.: +45 86 92 18 33<br />
Fax: +45 86 92 22 18<br />
E-mail: heatdesign@hwam.com<br />
Erklærer hermed, at<br />
Produkt: Type: Nr.:<br />
Brændeovn <strong>HWAM</strong> <strong>Monet</strong> med vandtank 117<br />
er fremstillet i overensstemmelse med bestemmelserne i følgende direktiver:<br />
Reference nr.: Titel:<br />
89/106/EEC Construction Products – CPD<br />
samt følgende harmoniserede standarder:<br />
Nr: Titel: Udgave:<br />
EN 13240 Roomheaters fired by solid fuel 2001<br />
EN 13240/A2 Roomheaters fired by solid fuel 2004<br />
og andre standarder og/eller tekniske specifikationer<br />
Nr: Titel: Udgave: Del:<br />
NS 3058 Lukkede vedfyrte ildsteder Røykudslipp<br />
NS 3059 Lukkede vedfyrte ildsteder Røykudslipp<br />
- Krav<br />
Hørning, d. 21. maj 2007<br />
Torsten Hvam Pedersen<br />
Fabriks- og kvalitetschef
Skorstensfejerpåtegning:<br />
Dato Underskrift<br />
53-6088
Instructions for connection of a stove<br />
with domestic water heating<br />
The mounting and installation of an <strong>HWAM</strong> stove with domestic water heating must follow<br />
DIN 4751, page 2:<br />
1. This kind of heat generators is only permitted to be used with a kettle temperature not<br />
higher than 90°C.<br />
2. The heat exchanger is not permitted to be used for the purpose of heating the domestic<br />
water.<br />
3. The flow pressure available for heating the domestic water must account for at<br />
least 2 atmospheric pressures. If the water conduit falls down under 2 atmospheric<br />
pressures, for example at power failure by your own water supply and at failure<br />
by the circulating pump, then the kettle must immediately be taken out of function.<br />
4. Between the domestic water supply and the thermal drain securities no delimiter of the<br />
flow mass must be installed.<br />
5. As thermal drain security only a certified unit is allowed to be used, fulfilling the following<br />
demands:<br />
• Response temperature 95°C.<br />
• Flow rate with a sensor temperature of 110°C and a differential pressure at the thermo<br />
valve of 1 atmospheric pressure must be at least 200 kg per hour.<br />
• The procurement as well as the proper fitting of the required thermo valve is the responsibility<br />
of the installation firm.<br />
6. The maximum transport pressure in the joint piece is not permitted to exceed 2,5 mmWS.<br />
If this value is exceeded on the assembly place, then the chimney must be provided with<br />
a shunt appliance.<br />
7. The equalization vessel must be equipped at its highest point with an automatically functioning<br />
exhaust valve.<br />
Furthermore, when you fire with solid fuel you have to pay special attention to the following<br />
points:<br />
a. The water pressure in front of the thermal drain security must account for at least 2 atmospheric<br />
pressures, also at open thermal valve.<br />
b. It obliges the user to let a competent person control the thermal drain security at least once<br />
a year. At this occasion the scales and the slop, if any, should be removed from the thermal<br />
drain security. The thermal valve must in this connection be tested on its functionality.<br />
Important!<br />
The heat connection must always be done by a specialist (heating constructor). Only he knows<br />
how to connect the water-leading heat kettle of the stove in a skilled way and according to<br />
the DIN norms.
As to installations that are not done by a specialist we have to decline every warrantee.<br />
As regards professional installation, the person who made the installation is responsible<br />
for the construction.<br />
Connection to central heating system<br />
<strong>HWAM</strong> <strong>Monet</strong> can be connected to a new or an existing central heating system as a supplementary<br />
auxiliary kettle. The water supply must be connected at 4, and the return water from<br />
the woodburning stove must be connected the return line of the system. A part of the water<br />
supply will then circulate through the stove where it is heated further, before it is mixed with<br />
the colder return water.<br />
At the same time it is secured that there is always flow in the stove, no matter if the radiator<br />
thermostats of the heating system should be closed.<br />
Depending on the need for heat, the shunt valve can be set at ”summer position” for quickly<br />
utilization of the stove to heat other rooms with radiators. If the need for heat is not very important<br />
it might be necessary to set the shunt towards “winter position” to involve more water<br />
in the circulation. With the shunt in “winter position” the kettle heats domestic water.<br />
<strong>HWAM</strong> <strong>Monet</strong> connected to a central heating system<br />
1. Automatic aeration<br />
2. Vent<br />
3. Outlet<br />
4. Supply by AVTA valve<br />
5. Floor heating<br />
6. Radiator<br />
7. Supply<br />
18. Return<br />
19. Return conduit<br />
10. Oil-fired burner<br />
11. Hot water<br />
12. Expansion tank<br />
13. Shunt valve<br />
14. Pump
Total heating<br />
Simplified sketch for overall heating<br />
Open<br />
expansion tank<br />
<strong>HWAM</strong><br />
<strong>Monet</strong><br />
F3<br />
Pump<br />
Woodburning<br />
stove circuit<br />
1<br />
Safety valve<br />
Outlet<br />
T<br />
Mix 50°C<br />
M1<br />
Hot water<br />
tank<br />
Radiator circuit<br />
Hot<br />
domestic water<br />
Electric heating element<br />
Supply of cold water<br />
A: Woodburning stove circuit<br />
B: Radiator circuit<br />
C: Floor heating circuit<br />
T: Thermostat KP77<br />
M1: AT mix-valve<br />
1: Thermal drain security<br />
F3: Sensor<br />
Floor heating<br />
Domestic water and heating of rooms<br />
<strong>HWAM</strong> <strong>Monet</strong> can be connected with an automatically working mix-valve and a KP 77 thermostat<br />
intended to start the pumps. The system gives the hot domestic water the highest<br />
priority. Then the radiator circuit is involved for heating the rooms. However the convection<br />
system of the stove quickly gives off heat to the room. You get the best effect if the surplus<br />
heat is converted to floor heat. The floors act as a heat storage slowly giving off the heat<br />
to the rooms. The mix-valve secures that the water tank in <strong>HWAM</strong> <strong>Monet</strong> is always warmer<br />
than 50°C. This gives a better combustion and with that a higher efficiency.<br />
Function<br />
When you light the woodburning stove, the thermostat (T), having a sensor (F3) in the outlet<br />
socket piece of the stove, registers a higher temperature (over 60°C) and starts the circulation<br />
pump. The heat exchanger spiral in the multi-purpose tank is after a short heating<br />
session heating the hot domestic water. When the return water from the multi-purpose tank<br />
exceeds the setting of the mix valve (M1), the supply is little by little changing from + to -. In<br />
that way the radiator circuit is involved in the heating. The floor heating circuit is ruled by a<br />
thermo valve (VT) securing that the floor heat is not getting superheated.<br />
When the stove is burning out the KP77 thermostat closes the pump at 50-55°C. In this<br />
way the circuit stops, before the temperature is down on the about 40°C of the electrical<br />
stick.<br />
Floor heating<br />
circuit<br />
• The system should be frost-proof by a thermo fluid.<br />
• The stove must have the thermal safeguarding drain mounted according to instructions<br />
• There must always be flow in the system so the water tank of the stove can get rid of the<br />
heat.<br />
• The woodburning circuit should be as little as possible and must be well insulated.
Connection to solar collector system<br />
Connection together with solar collector<br />
<strong>HWAM</strong> <strong>Monet</strong> combined with a solar collector system of 4-6 m 2 and a multi-purpose tank<br />
of about 2-300 litres with extra spiral and electric heating element is a very good alternative<br />
to the traditional housing heating with oil-fired burner. During the summer period the solar<br />
collector manages the heating of the domestic water. In colder periods, such as spring and<br />
autumn, it is supplied with <strong>HWAM</strong> <strong>Monet</strong> that gives rapid convection heat to the room, and<br />
supplies the solar collector by heating the water in the upper half of the multi-purpose tank.<br />
During the winter period, <strong>HWAM</strong> <strong>Monet</strong> manages all the heating of the room, partly by<br />
direct convection heat and partly via radiator and floor heating. You will get the best effect<br />
if the surplus heats all the year can be converted to floor heating. The floor heating act as<br />
heat storage, slowly giving off heat to the rooms.<br />
The function of the solar collector system<br />
By heating the solar collector the sensor (F1) registers a higher temperature than the sensor<br />
(F2) in the multi-purpose tank, and the difference thermostat (DT) starts the circulation<br />
pump. The heat-exchanging mantle is lying around the bottom edge of the multi-purpose<br />
tank. In this way the solar collector is exploited in the best possible way, also on days with<br />
little radiation. Thereafter the electric heating element takes care of the further heating. The<br />
solar collector system must out of consideration for staying frost-proof work with antifreeze<br />
mixture.<br />
The function of the woodburning stove circuit<br />
When you light up in the woodburning stove, the thermostat (F3) having a sensor in the<br />
connecting branch of the woodburning stove registers a higher temperature (over 60°C)<br />
and starts the circulation pump. The heat-exchanging spiral in the top of the multi-purpose<br />
tank heats after a short heating session the 80 litres of water on top. When the return water<br />
from the combination tank exceeds the setting of the mix-valve (M1) the supply little by little<br />
changes from + to -. Then the radiator circuit is involved in the heating. The floor heating is<br />
ruled by a thermo valve (VT) securing that the floor heating is not getting too hot.<br />
• The system should be made frost-proof by an antifreeze mixture.<br />
• The safety conduit from the outlet socket piece of the stove must be made according to<br />
the regulations and closing off it is not allowed.<br />
• The surplus heat from the solar collector cannot be spread out to the radiator circuit.<br />
• The woodburning circuit should be as little as possible and must be well insulated.
<strong>HWAM</strong> <strong>Monet</strong> connected with a solar collector system<br />
Expansion<br />
tank<br />
F3<br />
2.<br />
Pump<br />
Woodburing<br />
stove circuit<br />
220V<br />
1.<br />
T<br />
Mix 50°<br />
Outlet<br />
M1<br />
Hot water<br />
tank<br />
8<br />
F2<br />
Electric stick<br />
Fresh water supply<br />
Radiator circuit<br />
F1<br />
220V<br />
DT<br />
Expansion<br />
tank<br />
Pump<br />
Floor heating<br />
Connection with geothermal energy system<br />
DT: Differential thermostat<br />
M1: AT Mix-ventil<br />
T: Thermostat KP 77<br />
Solar collector<br />
circuit<br />
Floor heating<br />
circuit<br />
<strong>HWAM</strong> <strong>Monet</strong> is connected normally to the central heating system between the supply<br />
and the return conduit so that some of the hot supply water is heated further, before it is<br />
mixed with the cold return water. As the hot return water is not good for the heat pump, it is<br />
necessary to insert a thermostat and a three-way valve, so the hot return water circulates<br />
around the pump.<br />
Function<br />
When heated in the stove, the sensor of the thermostat registers rising temperature in the<br />
return conduit, and the three-way valve will close the water around the heat pump and directly<br />
to the supply conduit. Therefore the heat pump will not register any consumption and<br />
will automatically declutch. When the stove burns out, the temperature in the return conduit<br />
will fall, and the three-way valve will once again let the cold water into the heat pump.<br />
<strong>HWAM</strong> <strong>Monet</strong> connected with geothermal heat system<br />
Heat pump<br />
Earth conductor<br />
Expansion<br />
tank<br />
Motor valve Thermostate<br />
M<br />
Sensor<br />
Supply<br />
conduit<br />
Bypass<br />
Pump<br />
Hot service<br />
water<br />
Sensor<br />
Admission<br />
AVTA-valve<br />
Drain<br />
Outlet<br />
1. Thermal drain security<br />
2. Safety valve<br />
Radiator<br />
Return<br />
conduit
Connection with automatically functioning AVTA valve<br />
1. Inlet 3/4" socket piece<br />
2. Outlet 1" socket piece<br />
3. Admission of cooking<br />
water<br />
4. Outlet of cooling water<br />
5. Sensing socket<br />
A. Supply conduit<br />
B. Return conduit<br />
C. E.g. AVTA valve 50 - 90°.<br />
C. Will open at rising<br />
C. temperature<br />
D. Automatic aeration<br />
E. Thermometer<br />
The connection secures together with correct firing the optimal utilization of the water kettle<br />
of the stove. By using a Danfoss AVTA valve 50-90°C, you can secure an outlet temperature<br />
from the stove’s water tank of 70-75°C, and in this way avoid condensed water at the<br />
water tank. At the same time a better secondary combustion is secured, as the fire is not<br />
cooled too much down.<br />
The AVTA valve is mounted at the pipe to the inlet socket piece of the stove (1) and with<br />
the sensor through a 1” cross into to water tank of the stove through the out socket piece<br />
(2). The valve is to be mounted in accordance with the instructions of the factory.<br />
If the outlet pipe and the security conduit go downwards, there should always be mounted<br />
an automatically aeration at the outlet pipe. Like that air pockets are avoided that could<br />
arise by overheating in the lighting stage. If the connection is carried upwards from the<br />
stove, a drain cock should be mounted at the inlet socket piece.<br />
9<br />
F. Manometer, if any<br />
G. Admission with cold<br />
water (domestic water)<br />
H. Thermal circuit breaker<br />
with sensor in connecting<br />
branch (5). Opens at<br />
90°C.<br />
I. Safety valve<br />
J. Outlet of the cooking coil<br />
K. Outlet
Declaration of Conformity<br />
Manufacturer:<br />
<strong>HWAM</strong> Heat Design AS<br />
Nydamsvej 53<br />
DK – 8362 Hørning<br />
Denmark<br />
Tel.: +45 86 92 18 33<br />
Fax: +45 86 92 22 18<br />
E-mail: heatdesign@hwam.com<br />
hereby declares that:<br />
Product: Type:<br />
Wood-burning stove <strong>HWAM</strong> <strong>Monet</strong> with watertank<br />
was manufactured in accordance with the provisions of the following directive:<br />
Reference no. Title:<br />
89/106/EEC Construction Products Directive – CPD<br />
and the following harmonised standards:<br />
No: Title: Version:<br />
EN 13240 Roomheaters fired by solid fuel 2001<br />
EN 13240/A2 Roomheaters fired by solid fuel 2004<br />
and other standards and/or technical specifications<br />
No: Title:<br />
NS 3058 Enclosed wood heaters - Smoke emission<br />
NS 3059 Enclosed wood heaters - Smoke emission<br />
- requirement<br />
Hørning, 21. May 2007<br />
20
Vorschriften für den Anschluss eines Ofens<br />
mit Brauchwasser-Erwärmung<br />
Die Aufstellung eines <strong>HWAM</strong> Kaminofens mit Brauchwasser-Erwärmung muss nach DIN<br />
4751, Blatt 2 erfolgen:<br />
1. Derartige Wärmeerzeuger dürfen nur mit einer höchsten Kesselwasservorlauftemperatur<br />
von 90°C betrieben werden.<br />
2. Der Wärmetauscher darf nicht zum Zweck der Brauchwasserbereitung benutzt werden.<br />
3. Der für den Brauchwasserbereiter zur Verfügung stehende Fließdruck muss mindestens<br />
2 atü betragen. Sofern der Wasserleitungsdruck unter 2 atü abfällt, z.B. Stromausfall bei<br />
Eigenwasserversorgung und Ausfall der Umwälzpumpe, muss der Kessel sofort außer<br />
Betrieb genommen werden.<br />
4. Zwischen Brauchwasserzufluss und thermischen Ablaufsicherungen dürfen keine Durchflussmengenbegrenzer<br />
eingebaut werden.<br />
5. Als thermische Ablaufsicherung darf nur ein bauteilgeprüftes Ventil verwendet werden, das<br />
folgende Anforderungen erfüllt:<br />
• Ansprechtemperatur 95°C.<br />
• Durchflussleistung bei einer Fühlertemperatur von 110°C und einem Differenzdruck am<br />
Thermoventil von 1 atü mindestens 200 kg pro Stunde.<br />
• Die Beschaffung und der sachgemässe Einbau des erforderlichen Thermoventils ist<br />
Pflicht der Installationsfirma.<br />
6. Der maximale Förderdruck im Verbindungsstück darf 2,5 mmWS nicht überschreiten. Wird<br />
dieser Wert am Aufstellungsort überschritten, so ist der Schornstein mit einer Nebenluftvorrichtung<br />
auszustatten.<br />
7. Das Ausgleichsgefäß ist an seinem höchsten Punkt mit einer automatisch wirkenden<br />
Entlüftung auszurüsten.<br />
Ferner ist bei der Verfeuerung von festen Brennstoffen auf folgende Punkte besonders zu<br />
achten:<br />
a) Der Wasserdruck von der thermischen Ablaufsicherung muss auch bei geöffnetem<br />
Thermoventil mindestens 2 atü betragen.<br />
b) Der Betreiber ist verplichtet, die thermische Ablaufsicherung mindestens einmal jährlich<br />
durch einen Sachkundigen prüfen zu lassen. Hierbei muss gegebenfalls die thermische<br />
Ablaufsicherung von Kesselstein und Schmutzwasser gereinigt werden. Das Thermoventil<br />
muss hierzu auf seine Funktionsfähigkeit überprüft werden.<br />
WICHTIG<br />
Der Heizanschluss ist in jedem Falle vom Fachmann zu erstellen (Heizungsbauer). Nur dieser<br />
ist in der Lage, den wassergeführten Kamin-Heizkessel fachgerecht und DIN-Normen<br />
entsprechend zu installieren.<br />
2
Bei nicht fachgerechter Installation müssen wir jegliche Gewährleistung ablehnen.<br />
Für die fachgerechte Installation ist der Errichter der Anlage zuständig.<br />
Anschluss an eine Zentralheizungsanlage<br />
Der <strong>HWAM</strong> <strong>Monet</strong> kann an einer neuen Zentralheizungsanlage angeschlossen werden, oder<br />
an einer bereits vorhandenen Anlage angekoppelt werden und an als ergänzenden Hilfskessel<br />
dienen. Das Vorlaufwasser muss bei 4 angeschlossen werden, und das Rücklaufwasser<br />
des Kaminofens ist an die Retourleitung anzuschließen. Ein Teil des Vorlaufwassers zirkuliert<br />
durch den Ofen und erfährt ein zusätzliche Erhitzung, bevor es sich mit dem kälteren Rücklaufwasser<br />
vermischt.<br />
Dadurch ist gleichzeitig dafür gesorgt, dass im Ofen stets ein Umlauf stattfindet, auch dann,<br />
wenn die Heizkörperthermostate der Heizungsanlage geschlossen sein sollten.<br />
Je nach Wärmebedarf lässt sich das Wechselventil in „Sommerposition“ bringen. Auf diese<br />
Weise kann der Ofen zur schnellen Erwärmung anderer Zimmer mit Heizkörpern genutzt<br />
werden. Bei geringerem Wärmebedarf kann es sich als notwendig erweisen, das Wechselventil<br />
auf „Winterposition“ zu stellen, um größere Wassermengen in den Umlauf einzubringen.<br />
Befindet sich das Wechselventil in „Winterposition“, wird das Nutzwasser im Kessel erhitzt.<br />
<strong>HWAM</strong> Kaminofen an eine Zentralheizungsanlage angeschlossen<br />
1. Entlüftung<br />
2. Thermische Ablaufsicherung<br />
3. Sicherheitsventil<br />
4. Zugang mit AVTA-Ventil<br />
5. Fussbodenwärme<br />
6. Heizkörper<br />
7. Vorlaufleitung<br />
8. Rücklaufleitung<br />
9. Rücklaufleitung<br />
10. Ölbrenner<br />
11. Warmwasser<br />
12. Ausdehnungsgefäß<br />
13. Wechselventil<br />
14. Pumpe<br />
22
Alleinheizung<br />
Grundsatzskizze für Alleinheizung mit <strong>HWAM</strong> <strong>Monet</strong> und Mix-Ventil<br />
<strong>HWAM</strong><br />
<strong>Monet</strong><br />
Ausdehnungsgefäß<br />
F3<br />
2<br />
Pumpe<br />
Kaminofenkreis<br />
1<br />
Abfluss<br />
220V<br />
T<br />
Mix 50°<br />
M1<br />
Warmwasserboiler<br />
Brauchwasser und Raumerwärmung<br />
<strong>HWAM</strong> <strong>Monet</strong> kann an ein automatisch wirkendes Wechselventil angeschlossen werden und<br />
an ein KP77 Thermostat, um die Pumpen in Betrieb zu setzen. Die Anlage bereitet zuerst das<br />
warme Brauchwasser. Danach wird der Heizkörperkreis für die Raumerwärmung eingespeist.<br />
Das Konvektionssystem des Ofens gibt aber schnell Wärme an die Räumen ab.<br />
Die beste Wirkung wird erreicht, wenn die überschüssige Wärme zu Bodenwärme gewechselt<br />
wird. Die Fussböden wirken als ein Wärmelager, das langsam die Wärme an die Räume abgibt.<br />
Das Wechselventil sichert, dass die Wassertemperatur im <strong>HWAM</strong> <strong>Monet</strong> immer über 50°C ist.<br />
Dieses ergibt eine bessere Verbrennung und damit einen höheren Wirkungsgrad.<br />
Funktion<br />
Wenn im Kaminofen geheizt wird, registriert das Thermostat (T), über einen Sensor (F3) im<br />
Abgangsstutzen des Ofens, eine höhere Temperatur (über 60°C) und setzt die Umwälzpumpe<br />
in Betrieb. Die Wechslerspirale im Kombigefäß erhitzt nach kurzer Feuerzeit das wärme Brauchwasser.<br />
Wenn das Rücklaufwasser des Kombigefäßes die Einstellung für das Wechselventil<br />
übersteigt (M1), wechselt der Zugang allmählich von + zu -. Damit wird der Heizkörperkreis<br />
in die Erwärmung aufgenommen. Der Bodenwärmekreis wird von einem Thermoventil (VT)<br />
gesteuert, das sichert, dass die Bodenwärme nicht überhitzt wird.<br />
Wenn der Ofen auf brennt, wird das KP77 Thermostat die Pumpe bei 50-55° C ausschalten.<br />
Damit hält der Kreislauf inne, bevor die Temperatur zu niedrig für den elektrischen Heizstab<br />
wird, etwa 40°C.<br />
2<br />
Frischwasser-<br />
Zuführung<br />
Heizkörperkreis<br />
Warmes<br />
Brauchwasser<br />
Elektrischer<br />
Heizstab<br />
VT<br />
T: Thermostat<br />
M1: Wechselventil<br />
F3: Messfühler<br />
VT: Thermostatventil<br />
1. Thermische Ablaufsicherung<br />
2. Sicherheitsventil<br />
Fussbodenheizungskreis<br />
Fussbodenheizung
• Die Anlage sollte mit Frostschutzmittel geschützt sein.<br />
• Der Ofen muss mit den Vorschriftsmäßigen thermischen Ablaufsicherungen montiert<br />
werden.<br />
• In der Anlage muss immer Durchfluss sein, so das der Wassertank des Ofens die Wärme<br />
abgeben kann.<br />
• Der Kaminofenkreislauf sollte möglichst klein und gut isoliert sein.<br />
Anschluss mit Erdwärme-Kollektoranlage<br />
<strong>HWAM</strong> <strong>Monet</strong> wird auf normale Weise an die Zentralheizungsanlage zwischen den Vorlauf- und<br />
Rücklaufleitungen eingekoppelt, so das ein Teil des warmen Vorlaufwassers ein zusätzliche<br />
Erhitzung erfährt, bevor es sich mit dem kalten Rücklaufwasser vermischt. Da die Wärmepumpe<br />
nicht kaltes Rücklaufwasser verträgt, sind vor der Wärmepumpe einen Thermostat und ein<br />
Wechselventil einzuschieben, damit das warme Rücklaufwasser um die Pumpe zirkuliert.<br />
Funktion<br />
Wenn im Ofen geheizt wird, registriert der Sensor des Thermostats eine steigende Temperatur<br />
in der Rücklaufleitung, das Wechselventil wird dann das Wasser um die Wärmepumpe herum<br />
leiten und direkt in die Vorlaufleitung einleiten. Die Wärmepumpe registriert damit keinen<br />
Verbrauch und schaltet automatisch aus. Wenn der Ofen ausbrennt, wird die Temperatur<br />
in der Rücklaufleitung sinken und das Wechselventil wird wieder das kalte Wasser in die<br />
Wärmepumpe leiten.<br />
<strong>HWAM</strong> <strong>Monet</strong> mit einer Erdwärme-Kollektoranlage zusammengeschlossen<br />
Wärmepumpe<br />
Erdkollektor<br />
Ausdehnungsgefäß<br />
Motorventil Thermostat<br />
M T<br />
Pumpe<br />
Vorlauf<br />
Fühler Rücklauf<br />
Abfluss<br />
2<br />
Fühler<br />
Eingang<br />
1. Thermische Ablaufsicherung<br />
2. Sicherheitsventil<br />
Abgang<br />
AVTA-Ventil<br />
Heizkörper
Anschluss an Sonnenkollektoranlage<br />
Anschluss zusammen mit Sonnenkollektor<br />
<strong>HWAM</strong> <strong>Monet</strong> kombiniert mit einer Sonnenkollektoranlage auf 4-6 m 2 und einem 2-300 Liter<br />
Kombigefäß mit zusätzlicher Spirale und elektrischem Heizstab ist eine besonders gute Alternative<br />
zur traditionellen Wohnungsaufwärmung mit Ölheizung. In der Sommerperiode besorgt<br />
der Sonnenkollektor die Erwärmung des Brauchwassers. In kälteren Perioden, wie Frühjahr<br />
und Herbst, wird mit <strong>HWAM</strong> <strong>Monet</strong> ergänzt, der schnell seine Konvektionswärme zum Raum<br />
abgibt, und hilft dem Sonnenkollektor, das Wasser in der oberen Hälfte des KombiGefäßes<br />
zu erwärmen. In der Winterperiode besorgt <strong>HWAM</strong> <strong>Monet</strong> die ganze Wohnungsaufwärmung,<br />
teils durch direkte Konvektionswärme, und teils durch Heizkörper und Bodenwärme. Die<br />
beste Wirkung bekommt man, wenn das ganze Jahr die Überschusswärme zu Bodenwärme<br />
gewechselt werden kann. Die Bodenwärme funktioniert als ein Wärmelager, das langsam die<br />
Wärme zu den Räumen abgibt.<br />
Die Funktion des Sonnenkollektorkreises<br />
Bei Erwärmung des Sonnenkollektors registriert der Sensor (F1) eine höhere Temperatur<br />
als der Sensor (F2) im Kombigefäß, und der Differenzthermostat startet die Umwälzpumpe.<br />
Der Wechselmantel liegt rund um den kalten Teil des Kombigefäßes. Dadurch wird der Sonnenkollektor<br />
am besten ausgenutzt, auch an Tagen mit kleiner Einstrahlung. Danach sorgt<br />
der elekstrische Heizstab für die weitere Erwärmung. Der Sonnenkollektorkreis muss mit<br />
Frostschutzmittel geschützt sein.<br />
Die Funktion des Kaminofenkreises<br />
Wenn im Ofen geheizt wird, registriert der Thermostat (F3), dessen Fühler im Fühlerstutzen<br />
des Ofens ist, eine höhere Temperatur (über 60° C) und startet die Umwälzpumpe. Die Wechselspirale<br />
im oberen Teil des Kombigefäßes erwärmt nach kurzer Zeit die oberen 80 Liter<br />
Wasser. Wenn das Retourwasser vom Kombigefäß die Einstellung des Wechselventils (M1)<br />
übersteigt, wechselt der Zugang allmählich von + bis -. Damit wird der Heizkörperkreis in die<br />
Erwärmung hineingezogen. Der Fussbodenheizungskreis wird von einem Thermoventil (VT)<br />
gesteuert, der sichert, dass die Fussbodenheizung nicht überhitzt wird.<br />
• Die Anlage sollte mit Frostschutzmittel geschützt sein.<br />
• Der Ofen muss mit den Vorschriftsmäßigen thermischen Ablaufsicherungen montiert<br />
werden.<br />
• Überschusswärme vom Sonnenkollektor kann nicht auf den Heizkörperkreis nicht verteilt<br />
werden.<br />
• Der Kaminofenkreislauf sollte möglichst klein und gut isoliert sein.<br />
2
<strong>HWAM</strong> <strong>Monet</strong> zusammen mit einer Sonnenkollektoranlage angeschlossen<br />
Ausdehnungsgefäß<br />
F3<br />
2.<br />
Pumpe<br />
Kaminofenkreis<br />
1.<br />
Abfluss<br />
T: Thermostat<br />
DT: Differenzthermostat<br />
1: Thermische Ablaufsicherung<br />
2: Sicherheitsventil<br />
220V<br />
T<br />
Mix 50°<br />
M1<br />
Warmwasserlager<br />
Bypass<br />
2<br />
Elektrischer<br />
Heizstab<br />
F2<br />
Warmes<br />
Brauchwasser<br />
Frischwasserzuführung<br />
Heizkörperkreis<br />
F1<br />
220V<br />
DT<br />
Offenes<br />
Ausdehnungsgefäß<br />
Pumpe<br />
Sonnenkollektorkreis<br />
Fussbodenheizungskreis<br />
Fussbodenheizung
Anschluss mit Thermosicherung<br />
und geschlossener Expansion<br />
1. Zugangstutzen 3/4"<br />
2. Abgangstutzen 1"<br />
3. Zugang Kühlwasser<br />
4. Abgang Kühlwasser<br />
5. Fühlermuffe<br />
A. Vorlaufleitung.<br />
B. Rücklaufleitung.<br />
C. Z.B. AVTA-Ventil 50-90°C.<br />
Öffnet bei steigender Temperatur.<br />
D. Automatischer Luftauslass.<br />
E. Thermometer.<br />
F. Eventuelles Manometer.<br />
Der Anschluss sichert zusammen mit einer korrekten Feuerung die optimale Ausnutzung<br />
des Wasserkessels des Ofens. Durch die Verwendung eines AVTA-Ventils 50-90°C wird eine<br />
Abgangstemperatur von 70-75°C gewährleistet und somit wird Kondenswasser auf dem<br />
Kessel vermeidet. Gleichzeitig wird eine bessere Nachverbrennung gesichert, da das Feuer<br />
nicht zu hart heruntergekühlt wird.<br />
Das AVTA-Ventil wird auf das Rohr für den Zugangstutzen des Ofens (1) und mit dem Sensor<br />
durch ein 1" Kreuz in den Wasserkessel des Ofens durch den Abgangstutzen (2) montiert.<br />
Das Ventil muss nach den Anweisungen der Fabrik montiert werden.<br />
Wenn das Abgangsrohr nach unten geleitet wird, sollte ein automatischer Entlüftungshahn auf<br />
das Abgangsrohr immer montiert werden. Dadurch werden Lufttaschen, die bei Überhitzung<br />
in der Einheizungsphase entstehen können, vermieden. Wenn der Anschluss vom Ofen nach<br />
oben geleitet wird, sollte ein Abflusshahn auf den Zugang-stutzen montiert werden.<br />
2<br />
G. Zugang mit kaltem Wasser<br />
(Brauchwasser).<br />
H. Thermosicherung mit Sensor<br />
in Sensorstutzen (5). Öffnet<br />
bei 90°C.<br />
I. Sicherheitsventil.<br />
J. Ablauf von Kühlspirale.<br />
K. Abgangsrohr.
Säkerhetsmässiga krav enligt lagen<br />
Anslutning av en vattentank ska ske i enlighet med arbetsinspektionens publikation nr 42<br />
“Föreskrifter för eldade varmvattensystem” och gällande nationella och lokala standarder.<br />
I dessa hänvisas särskilt till avsnitt 2 om bland annat en säkerhetsledning till en öppen<br />
expansionsbehållare. Säkerhetsledningen ska se till att kaminens värmepanna kan göra<br />
sig av med trycket om den kokar på grund av bristande genomströmning (till exempel vid<br />
strömavbrott).<br />
Om vattnet i tanken/värmepannan kokar trycks vattnet ut genom säkerhetsledningen till den<br />
öppna expansionsbehållaren. Expansionsbehållaren ska därför isoleras vid golv och utlopp<br />
så att det inte kan uppkomma vattenskada. Expansionsbehållaren ska dimensioneras så att<br />
den kan rymma utvidgningen av vattnet i systemet när det värms upp från 0 °C till 100 °C. I<br />
praktiken 4-8 %.<br />
Expansionsbehållaren och säkerhetsledningen ska vara frostsäkrade.<br />
Expansionsbehållarens vattennivå ska kontrolleras regelbundet. När systemet luftats eller om<br />
expansionsbehållaren kokat över ska vattennivån kontrolleras och eventuellt fyllas på.<br />
1. <strong>HWAM</strong> <strong>Monet</strong> med vattentank.<br />
2. Utgångsrör (överst 1”).<br />
3. Säkerhetsledning, minsta invändiga diameter<br />
för stålrör: 21,6 mm, för kopparrör: 19,5<br />
mm. Max. längd: 20 m, max. höjd: 10 m.<br />
Det får inte gå att stänga av säkerhetsledningen.<br />
Se ev. Arbetarinspektionens<br />
publikation nr 42 “Anvisningar för eldade<br />
varmvattensystem”.<br />
4. Öppen expansionsbehållare. Ska kunna<br />
rymma upp till 8 % av systemets totala<br />
vatten-innehåll.<br />
5. Ø 15 mm hävertbrytare.<br />
6. Skvallerledning och överkokning. Dras till<br />
golvet och ska vara snett avskuren.<br />
7. Golvutlopp.<br />
8. Påfyllnings- och avtappningskran.<br />
9. Retur.<br />
10. Tillopp.<br />
11. Automatisk luftutsläpp.<br />
T. Termometer, ska kunna mäta upp till 120<br />
°C<br />
M. Manometer med röd markering vid högsta<br />
vattenpelare. T + M kan kombineras.<br />
28
Säkerhetsledningen, som dessutom kan fungera som returledning till centralpannan, ska<br />
utgå från kaminens toppanslutning. Värmeytan på <strong>HWAM</strong> <strong>Monet</strong> är 0,28 m och därför ska<br />
den anslutas med försänkt säkerhetsledning. Sedan behöver du bara montera en automatisk<br />
avluftare (11) på den högsta punkten efter utloppsanslutningen.<br />
Anslutning till centralvärmeanläggning<br />
<strong>HWAM</strong> <strong>Monet</strong> kan anslutas till en ny centralvärmeanläggning eller kopplas som extra panna<br />
till en befintlig sådan. Framledningsvattnet ska anslutas till 4 och utloppsvattnet från braskaminen<br />
ska anslutas till anläggningens returledning. En viss mängd av framledningsvattnet<br />
kommer att cirkulera i kaminen och värms upp ytterligare innan det blandas med det svalare<br />
returvattnet.<br />
Samtidigt säkerställs att det alltid är genomströmning i kaminen – även om värmeanläggningens<br />
radiatortermostater skulle vara stängda.<br />
Beroende på uppvärmningsbehovet kan shuntventilen ställas in på “sommarinställning”,<br />
vilket innebär att kaminen kan utnyttjas för att snabbt värma upp andra rum med element.<br />
Om behovet av uppvärmning inte är särskilt stort kan du vara tvungen att ställa in shunten<br />
på ”vinterinställning” för att få mer vatten i cirkulation. När shunten står på ”vinterinställning”<br />
värms tappvatten upp med pannan.<br />
<strong>HWAM</strong> <strong>Monet</strong> ansluten till en centralvärmeanläggning<br />
1. <strong>HWAM</strong> <strong>Monet</strong><br />
2. Avluftning<br />
3. Utlopp<br />
4. Inlopp med AVTA-ventil<br />
5. Golvvärme<br />
6. Radiator<br />
7. Framledning<br />
29<br />
8. Retur<br />
9. Retur- och säkerhetsledning<br />
10. Oljepanna<br />
11. Varmt vatten<br />
12. Öppet expansionskärl<br />
13. Shuntventil<br />
14. Pump
Totaluppvärmning<br />
Principskiss för totaluppvärmning<br />
<strong>HWAM</strong><br />
<strong>Monet</strong><br />
Öppet<br />
expansionskärl<br />
Kaminkrets<br />
Varmvattenbehållare<br />
Tappvatten och rumsuppvärmning<br />
<strong>HWAM</strong> <strong>Monet</strong> kan anslutas till en automatisk blandarventil och en KP77-termostat som startar<br />
pumparna. Anläggningen utnyttjar först det varma tappvattnet. Sedan aktiveras radiatorkretsen<br />
för rumsuppvärmning. Kaminens konvektionssystem sprider snabbt värme i rummet. Bäst<br />
verkan blir det om du låter överskottsvärmen växla över till golvvärme. Golven fungerar då<br />
som en värmebuffert som långsamt avger värme i rummen. Blandarventilen ser till att temperaturen<br />
i vattentanken på <strong>HWAM</strong> <strong>Monet</strong> alltid ligger över 50 °C. Det ger bättre förbränning<br />
och därmed högre verkningsgrad.<br />
Funktion<br />
När du tänder brasan i kaminen registrerar termostaten (T), som har en sensor (F3) i kaminens<br />
utloppsanslutning, att temperaturen höjts (över 60 °C) och startar cirkulationspumpen. Efter<br />
en stunds eldning värmer växlarslingan i kombibehållaren upp det varma tappvattnet. När returvattnet<br />
från kombibehållaren överskrider blandarventilens (M1) inställning ändras tillförseln<br />
efterhand från + till -, vilket leder till att radiatorkretsen omfattas av uppvärmningen. Golvvärmekretsen<br />
styrs av en termoventil (VT) som ser till att det inte blir överhettning i golvvärmen.<br />
När elden slocknar i kaminen kommer KP77-termostaten att stänga av pumpen vid 50–55 °C,<br />
vilket i sin tur leder till att cirkulationen stannar innan temperaturen är nere på elstavens<br />
ca 40 °C.<br />
• Anläggningen bör skyddas med frostskydd.<br />
• Säkerhetsledningen från kaminens utloppsanslutning måste alltid dras enligt gällande<br />
föreskrifter och det får inte vara möjligt att spärra den.<br />
• Det måste alltid vara cirkulation i anläggningen så att kaminens vattentank kan bli av med<br />
värmen.<br />
• Kaminkretsen bör vara så liten som möjligt och välisolerad.<br />
0<br />
Utlopp varmvatten<br />
Elstav<br />
Radiatorkrets<br />
Inlopp kallvatten<br />
T: Termostat KP77<br />
M1: AT blandarventil<br />
VT: Termostatventil<br />
Radiator Pump<br />
Golvvärme<br />
Golvvärmekrets
Anslutning till solfångaranläggning<br />
Anslutning till solfångare<br />
<strong>HWAM</strong> <strong>Monet</strong> som kombineras med en solfångaranläggning på 4–6 m 2 och en kombitank på<br />
200–300 l med extra slinga och elstav är ett mycket bra alternativ till vanlig uppvärmning med<br />
oljepanna. Under sommaren sköter solfångaren uppvärmningen av tappvattnet. Under de kyligare<br />
perioderna, som vår och höst, används dessutom <strong>HWAM</strong> <strong>Monet</strong> som snabbt avger konvektionsvärme<br />
i rummet och kompletterar solfångaren genom att värma upp vattnet i kombitankens övre<br />
halva. Under vintern sköter <strong>HWAM</strong> <strong>Monet</strong> all uppvärmning, dels via direkt konvektionsvärme,<br />
dels via radiatorer och golvvärme. Bäst verkan blir det om du låter överskottsvärmen växla<br />
över till golvvärme året runt. Golvvärmen fungerar som en värmebuffert som långsamt avger<br />
värme i rummen.<br />
Solfångarkretsens funktion<br />
Vid uppvärmning av solfångaren registrerar sensorn (F1) högre temperatur än sensorn (F2) i<br />
kombibehållaren och differenstermostaten (DT) startar cirkulationspumpen. Värmeväxlarmanteln<br />
ligger runt kombibehållarens nedre del. Därmed utnyttjas solfångaren bäst, även mulna<br />
dagar. Sedan sköter elstaven den fortsatta uppvärmningen. På grund av risken för frostskador<br />
ska det finnas frostskydd i solfångarkretsen.<br />
Kaminkretsens funktion<br />
När du tänder brasan i kaminen registrerar termostaten (F3), som har en sensor i kaminens<br />
givaranslutning, att temperaturen höjts (över 60 °C) och startar cirkulationspumpen. Efter en<br />
stunds eldning värmer växlarslingan i kombibehållarens topp upp de översta 80 l vatten . När<br />
returvattnet från kombibehållaren överskrider blandarventilens (M1) inställning ändras tillförseln<br />
efterhand från + till -, vilket leder till att radiatorkretsen omfattas av uppvärmningen. Golvvärmekretsen<br />
styrs av en termoventil (VT) som ser till att det inte blir överhettning i golvvärmen.<br />
• Anläggningen bör skyddas med frostskydd.<br />
• Säkerhetsledningen från kaminens utloppsanslutning måste dras enligt gällande föreskrifter<br />
och det får inte vara möjligt att spärra den.<br />
• Överskottsvärme från solfångaren kan inte överföras till radiatorkretsen.<br />
• Kaminkretsen bör vara så liten som möjligt och välisolerad.<br />
<strong>HWAM</strong> <strong>Monet</strong> ansluten till solfångaranläggning<br />
Öppet<br />
expansionskärl<br />
F3<br />
Pump<br />
Kaminkrets<br />
220V<br />
T<br />
Kombi-<br />
DT: Differenstermostat<br />
M1: AT blandarventil<br />
T: Termostat KP 77<br />
behållare<br />
Utlopp<br />
varmvatten F1<br />
Elstav 220V<br />
Solfångarkrets<br />
Tryck-<br />
DT<br />
F2<br />
expansionskärl<br />
Pump<br />
Inlopp kallvatten<br />
Radiator Pump<br />
M1<br />
Bypass<br />
Golvvärmekrets<br />
Golvvärme
Anslutning till jordvärmeanläggning<br />
<strong>HWAM</strong> <strong>Monet</strong> kopplas som vanligt in mellan centralvärmeanläggningens fram- och returledning<br />
så att en del av det varma framledningsvattnet värms upp ytterligare innan det blandas med<br />
det kalla returvattnet. Eftersom värmepumpen inte tål varmt returvatten måste en termostat<br />
och en trevägsventil monteras framför den så att det varma returvattnet leds förbi.<br />
Funktion<br />
När du eldar i kaminen registrerar termostatens sensor att temperaturen i returledningen<br />
stiger och trevägsventilen leder vattnet förbi värmepumpen och direkt till framledningen.<br />
Värmepumpen registrerar alltså inte någon förbrukning och stängs av automatiskt. När elden<br />
slocknar faller temperaturen i returledningen och trevägsventilen släpper åter in det kalla<br />
vattnet i värmepumpen.<br />
<strong>HWAM</strong> <strong>Monet</strong> ansluten till jordvärmeanläggning<br />
Jordslangar<br />
Värmepump<br />
Motorventil Termostat<br />
M T<br />
Sensor<br />
Framledning<br />
2<br />
Öppet<br />
expansionskärl<br />
Utlopp<br />
Sensor<br />
Inlopp<br />
Säkerhetsledning<br />
AVTA-ventil<br />
Radiator<br />
Returledning
Anslutning till automatiskt verkande AVTA-ventil<br />
1. Inlopp 3/4” muff.<br />
2. Utlopp 1” muff.<br />
3. Sensormuff 3/4”<br />
A. Tilloppsledning.<br />
B. Returledning och kaminens<br />
säkerhetsledning med anslutning<br />
till en öppen expansionsbehållare.<br />
C. AVTA-ventil. Öppnar vid stigande<br />
temperatur över 50 °C.<br />
D. Automatiskt luftutsläpp<br />
E. Termometer.<br />
F. Eventuell manometer.<br />
Tillsammans med korrekt eldning säkrar anslutningen ett optimalt utnyttjande av kaminens<br />
vattenpanna. Genom att använda en Danfoss AVTA-ventil 50-90 °C går det att säkerställa en<br />
utloppstemperatur från kaminens vattenbehållare på 70-75 °C och därigenom undvika kondensvatten<br />
på vattentanken. Detta säkerställer längre livslängd för vattentanken när det gäller<br />
korrosion och samtidigt en bättre efterförbränning genom att elden inte kyls ner för snabbt.<br />
AVTA-ventilen monteras på röret till kaminens tilloppsmuff (1) och monteras med sensorn<br />
genom sensormuffen (2). Ventilen ska monteras enligt anvisningarna från fabriken.<br />
Om utloppsröret och säkerhetsledningen går neråt bör det alltid monteras en automatisk<br />
avluftare på utloppsröret. Därmed undviks luftfickor som kan uppstå vid överhettning i antändningsfasen.<br />
Om anslutningen går uppåt från kaminen bör du montera en tappkran på<br />
inloppsanslutningen.<br />
Det är förbjudet och farligt att blockera säkerhetsledningen med kran, pump eller<br />
liknande.
DK-8362 Hørning<br />
heatdesign@hwam.com<br />