28.07.2013 Views

HWAM Monet

HWAM Monet

HWAM Monet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

09.2008<br />

<strong>HWAM</strong> <strong>Monet</strong><br />

Installation af vandtank • Installation of boiler<br />

Installation von Wassertank • Bruksanvisning


Indholdsfortegnelse, dansk<br />

Sikkerhedsmæssige lovkrav ................................................................................................................. 5<br />

Tilslutning til centralvarmeanlæg .......................................................................................................... 6<br />

Totalopvarmning ................................................................................................................................... 7<br />

Tilslutning til solfangeranlæg ................................................................................................................ 8<br />

Tilslutning sammen med jordvarmeanlæg ............................................................................................ 9<br />

Tilslutning med automatisk virkende AVTA-ventil ............................................................................... 10<br />

Overensstemmelseserklæring ............................................................................................................ 11<br />

Table of content, English<br />

Instructions for connection of a stove with domestic water heating .................................................... 14<br />

Connection to central heating system ................................................................................................ 15<br />

Total heating ....................................................................................................................................... 16<br />

Connection to solar collector system .................................................................................................. 17<br />

Connection with geothermal energy system ...................................................................................... 18<br />

Connection with automatically functioning AVTA valve ....................................................................... 19<br />

Inhaltsverzeichnis, Deutsch<br />

Vorschriften für den Anschluss eines Ofens mit Brauchwasser-Erwärmung ...................................... 21<br />

Anschluss an eine Zentralheizungsanlage ......................................................................................... 22<br />

Alleinheizung ...................................................................................................................................... 23<br />

Anschluss mit Erdwärme-Kollektoranlage .......................................................................................... 24<br />

Anschluss an Sonnenkollektoranlage ................................................................................................. 25<br />

Anschluss mit Thermosicherung und geschlossener Expansion ....................................................... 27<br />

Innehållsförteckning, svensk<br />

Säkerhetsmässiga krav enligt lagen ................................................................................................... 28<br />

Anslutning till centralvärmeanläggning ............................................................................................... 29<br />

Totaluppvärmning ............................................................................................................................... 30<br />

Anslutning till solfångaranläggning ..................................................................................................... 31<br />

Anslutning till jordvärmeanläggning .................................................................................................... 32<br />

Anslutning till automatiskt verkande AVTA-ventil ................................................................................ 33


Sikkerhedsmæssige lovkrav<br />

Tilslutning af vandtank skal ske i henhold til Arbejdstilsynets publikation nr. 42 "Forskrifter for<br />

fyrede varmtvandsanlæg". Heri henvises specielt til afsnit 2 om blandt andet sikkerhedsledning<br />

til åben ekspansionsbeholder. Sikkerhedsledningen skal sikre, at ovnens kedel kan komme af<br />

med trykket, hvis den på grund af manglende gennemstrømning (for eksempel ved strømsvigt)<br />

skulle komme i kog.<br />

Hvis vandet i tanken/kedlen koger, vil vandet blive trykket ud gennem sikkerhedsledningen<br />

til den åbne ekspansionsbeholder. Ekspansionsbeholderen skal derfor afsluttes ved gulv og<br />

afløb, så der ikke kan ske vandskade. Ekspansionsbeholderen skal dimensioneres, så den kan<br />

optage udvidelsen af anlæggets vand, når det opvarmes fra 0°C til 100°C. I praksis 4-8%.<br />

Ekspansionsbeholderen og sikkerhedsledningen skal være frostsikret.<br />

Dansk<br />

Ekspansionsbeholderens vandstand skal jævnligt kontrolleres. Efter udluftning af anlægget,<br />

eller hvis der er kogt vand ud gennem ekspansionsbeholderens overløb, skal vandstanden<br />

kontrolleres og eventuelt efterfyldes.<br />

1. <strong>HWAM</strong> <strong>Monet</strong> brændeovn med vandkedel.<br />

2. Afgangsstuds (øverst 1").<br />

3. Sikkerhedsledning, mindste indvendige<br />

diameter for stålrør: 21,6 mm, for kobberrør:<br />

19,5 mm.<br />

Max. længde: 20 m, max. højde: 10 m.<br />

Sikkerhedsledningen må ikke kunne<br />

afspærres.<br />

4. Åben ekspansionsbeholder. Skal kunne<br />

rumme op til 8% af anlæggets samlede<br />

vandindhold.<br />

5. Ø 15 mm hævertbryder.<br />

6. Meldeledning og overløb. Føres til gulv og<br />

skal være skråt afskåret.<br />

7. Gulvafløb.<br />

8. Påfyldnings- og aftapningshane.<br />

9. Fremløb<br />

10. Retur.<br />

11. Automatisk luftudlader.<br />

T. Termometer, skal kunne måle op til 120°<br />

C<br />

M. Manometer med rød markering ved højeste<br />

vandsøjle. T + M kan være kombineret.


Sikkerhedsledningen, som samtidig kan være returledningen til centralfyret, skal udgå fra<br />

ovnens topstuds. <strong>HWAM</strong> <strong>Monet</strong>'s hedeflade udgør 0,28 m og må derfor tilsluttes med dykket<br />

sikkerhedsledning. Der skal så blot på det højeste punkt efter afgangsstudsen monteres en<br />

automatisk luftudlader (11).<br />

Tilslutning til centralvarmeanlæg<br />

<strong>HWAM</strong> <strong>Monet</strong> kan tilsluttes et nyt eller indkobles på et eksisterende centralvarmeanlæg som<br />

en supplerende hjælpekedel. Fremløbsvandet skal tilsluttes ved 4, og afgangsvandet fra<br />

brændeovnen skal tilsluttes anlæggets returlinie. En del af fremløbsvandet vil så cirkulere gennem<br />

ovnen, hvor det varmes yderligere op, inden det blandes med det koldere returvand.<br />

Samtidig sikres det, at der altid er gennemstrømning i ovnen, uanset om varmeanlæggets<br />

radiatortermostater skulle være lukkede.<br />

Afhængig af varmebehovet kan shuntventilen stilles på "sommerstilling" for hurtig udnyttelse<br />

af ovnen til opvarmning af andre rum med radiatorer. Er varmebehovet ikke særligt stort, kan<br />

det blive nødvendigt at sætte shunten over mod "vinterstilling" for at inddrage mere vand i<br />

cirkulationen. Med shunten i "vinterstilling" opvarmes brugsvand med kedlen.<br />

<strong>HWAM</strong> <strong>Monet</strong> tilsluttet et centralvarmeanlæg<br />

1. <strong>HWAM</strong> <strong>Monet</strong><br />

2. Udluftning<br />

3. Afgang<br />

4. Tilgang med AVTA-ventil<br />

5. Gulvvarme<br />

6. Radiator<br />

7. Fremløb<br />

8. Retur<br />

9. Retur- og sikkerhedsledning<br />

10. Oliefyr<br />

11. Varmt vand<br />

12. Åben ekspansionsbeholder<br />

13. Shuntventil<br />

14. Pumpe


Totalopvarmning<br />

Principskitse for totalopvarmning<br />

<strong>HWAM</strong><br />

<strong>Monet</strong><br />

Åben<br />

ekspansionsbeholder<br />

Brændeovnskreds<br />

Varmtvandsbeholder<br />

Radiatorkreds<br />

Afgang varmt vand<br />

El-stav<br />

Tilgang koldt vand<br />

Radiator Pumpe<br />

T: Termostat KP77<br />

M1: AT mix-ventil<br />

VT: Termostatventil<br />

Gulvvarmekreds<br />

Gulvvarme<br />

Brugsvand og rumopvarmning<br />

<strong>HWAM</strong> <strong>Monet</strong> kan tilsluttes en automatisk virkende mix-ventil og en KP77 termostat til at<br />

starte pumperne. Anlægget prioriterer først det varme brugsvand. Derefter inddrages radiatorkredsen<br />

til rumopvarmning. Ovnens konvektionssystem afgiver dog hurtigt varme til<br />

rummet. Bedst virkning får man, hvis overskudsvarmen veksles over til gulvvarme. Gulvene<br />

virker som et varmelager, der langsomt afgiver varmen til rummene. Mix-ventilen sikrer, at<br />

vandtanken i <strong>HWAM</strong> <strong>Monet</strong> altid er over 50°C. Dette giver en bedre forbrænding og dermed<br />

en højere virkningsgrad.<br />

Funktion<br />

Når der tændes op i brændeovnen, registrerer termostaten (T), som har en føler (F3) i ovnens<br />

afgangsstuds, en højere temperatur (over 60°C) og starter cirkulationspumpen. Vekslerspiralen<br />

i kombibeholderen opvarmer efter kort tids fyring det varme brugsvand. Når returvandet fra<br />

kombibeholderen overstiger mix-ventilens (M1) indstilling, skifter tilgangen efterhånden fra +<br />

over til -. Derved inddrages radiatorkredsen i opvarmningen. Gulvvarmekredsen styres af en<br />

termoventil (VT), som sikrer, at gulvvarmen ikke overophedes.<br />

Når ovnen brænder ud, vil KP77 termostaten slukke pumpen ved 50-55°C. Derved stopper<br />

kredsløbet, inden temperaturen er nede på el-stavens ca. 40°C.<br />

• Anlægget bør frostsikres med termovæske.<br />

• Sikkerhedsledningen fra ovnens afgangsstuds skal altid udføres forskriftsmæssigt og må<br />

ikke kunne afspærres.<br />

• Der skal altid være gennemstrømning på anlægget, så ovnens vandtank kan komme af<br />

med varmen.<br />

• Brændeovnskredsen bør være så lille som mulig og være velisoleret.


Tilslutning til solfangeranlæg<br />

Tilslutning sammen med solfanger<br />

<strong>HWAM</strong> <strong>Monet</strong>, kombineret med et solfangeranlæg på 4-6 m 2 og en ca. 2-300 l kombitank med<br />

ekstra spiral og el-stav, er et særdeles godt alternativ til den traditionelle boligopvarmning<br />

med oliefyr. I sommerperioden klarer solfangeren opvarmningen af brugsvandet. I koldere<br />

perioder, som forår og efterår, suppleres med <strong>HWAM</strong> <strong>Monet</strong>, som giver hurtig konvektionsvarme<br />

til rummet, og supplerer solfangeren ved at opvarme vandet i den øverste halvdel af<br />

kombitanken. I vinterperioden klarer <strong>HWAM</strong> <strong>Monet</strong> hele rumopvarmningen dels ved direkte<br />

konvektionsvarme, og dels via radiator og gulvvarme. Bedst virkning får man, hvis overskudsvarmen<br />

året rundt kan veksles over til gulvvarme. Gulvvarmen virker som et varmelager, der<br />

langsomt afgiver varmen til rummene.<br />

Solfangerkredsens funktion<br />

Ved opvarmning af solfangeren registrerer føleren (F1) en højere temperatur end føleren (F2)<br />

i kombibeholderen, og differenstermostaten (DT) starter cirkulationspumpen. Vekslerkappen<br />

ligger rundt om kombibeholderens nederste ende. Derved udnyttes solfangeren bedst muligt,<br />

også på dage med lille indstråling. Derefter sørger el-staven for den videre opvarmning.<br />

Solfangerkredsen skal af hensyn til frostsikring arbejde med termovæske.<br />

Brændeovnskredsens funktion<br />

Når der tændes op i brændeovnen, registrerer termostaten (F3), som har en føler i ovnens<br />

følerstuds, en højere temperatur (over 60°C) og starter cirkulationspumpen. Vekslerspiralen<br />

i kombibeholderens top opvarmer efter kort tids fyring de øverste 80 l vand. Når returvandet<br />

fra kombibeholderen overstiger mix-ventilens (M1) indstilling, skifter tilgangen efterhånden<br />

fra + over til -. Derved inddrages radiatorkredsen i opvarmningen. Gulvvarmekredsen styres<br />

af en termoventil (VT), som sikrer, at gulvvarmen ikke overophedes.<br />

• Anlægget bør frostsikres med termovæske.<br />

• Sikkerhedsledningen fra ovnens afgangsstuds skal udføres forskriftsmæssigt<br />

og må ikke kunne afspærres.<br />

• Overskudsvarme fra solfangeren kan ikke fordeles ud på radiatorkredsen.<br />

• Brændeovnskredsen bør være så lille som mulig og være velisoleret.<br />

<strong>HWAM</strong> <strong>Monet</strong> tilsluttet sammen med et solfangeranlæg<br />

Ekspansionsbeholder<br />

F3<br />

Pumpe<br />

Brændeovnskreds<br />

220V<br />

T<br />

M1<br />

Kombibeholder<br />

Bypass<br />

Radiatorkreds<br />

Varmt<br />

brugsvand<br />

F1<br />

El-stav<br />

220V<br />

Tryk-<br />

DT<br />

F2<br />

ekspansionsbeholder<br />

Tilgang koldt vand<br />

8<br />

Radiator<br />

Solfangerkreds<br />

Pumpe<br />

Pumpe<br />

VT<br />

Gulvvarme<br />

Gulvvarmekreds<br />

DT: Differenstermostat<br />

M1: AT Mix-ventil<br />

T: Termostat KP 77


Tilslutning sammen med jordvarmeanlæg<br />

<strong>HWAM</strong> <strong>Monet</strong> kobles på normal vis ind på centralvarmeanlægget mellem fremløbs- og<br />

returledningen, således at noget af det varme fremløbsvand opvarmes yderligere, før det<br />

blandes med det kolde returvand. Da varmepumpen ikke tåler varmt returvand, skal der før<br />

varmepumpen indskydes en termostat og en trevejsventil, så det varme returvand cirkulerer<br />

uden om varmepumpen.<br />

Funktion<br />

Når der fyres i ovnen, registrerer termostatens føler stigende temperatur i returledningen,<br />

og trevejsventilen vil lukke vandet uden om varmepumpen og føre det direkte over i fremløbsledningen.Varmepumpen<br />

vil således ikke registrere noget forbrug og vil automatisk koble<br />

ud. Når ovnen brænder ud, vil temperaturen i returledningen falde, og trevejsventilen vil igen<br />

lukke det kolde vand ind i varmepumpen.<br />

<strong>HWAM</strong> <strong>Monet</strong> tilsluttet sammen med jordvarmeanlæg<br />

Varmepumpe<br />

Jordslanger<br />

Motorventil<br />

M<br />

Føler<br />

Termostat<br />

T<br />

Fremløb<br />

9<br />

Ekspansionsbeholder<br />

Afgang<br />

Føler<br />

Tilgang<br />

Sikkerhedsledning<br />

AVTA-ventil<br />

Radiator<br />

Returledning


Tilslutning med automatisk virkende AVTA-ventil<br />

1. Tilgang 3/4" studs.<br />

2. Afgang 1" studs.<br />

3. Følermuffe 3/4"<br />

A. Fremløbsledning.<br />

B. Returledning og ovnens sikkerhedsledning<br />

med forbindelse til<br />

åben ekspansion.<br />

C. AVTA-ventil. Åbner ved stigende<br />

temperatur over 50°C.<br />

Tilslutningen sikrer sammen med en korrekt fyring den optimale udnyttelse af ovnens vandkedel.<br />

Ved at anvende en Danfoss AVTA-ventil 50-90°C kan man sikre en afgangstemperatur fra<br />

ovnens vandbeholder på 70-75°C og derved undgå kondensvand på vandtanken. Samtidig<br />

sikres en bedre efterforbrænding, idet bålet ikke køles for hårdt ned.<br />

AVTA-ventilen monteres på røret til ovnens tilgangsstuds (1) og monteres med føleren gennem<br />

Følermuffen ind i ovnens vandkedel. Ventilen skal monteres ifølge fabrikkens anvisninger.<br />

Såfremt afgangsrøret og sikkerhedsledningen går nedad, bør der altid monteres en automatisk<br />

luftudlader på afgangsrøret. Derved undgås luftlommer, som kan opstå ved overfyring i<br />

optændingsfasen. Føres tilslutningen opad fra ovnen, bør der monteres en aftap-ningshane<br />

på tilgangsstudsen.<br />

Det er forbudt og farligt at blokere sikkerhedsledningen med hane, pumpe eller lignende.<br />

0<br />

D. Automatisk luftudlader.<br />

E. Termometer.<br />

F. Eventuelt manometer.


Overensstemmelseserklæring<br />

Fabrikant:<br />

<strong>HWAM</strong> Heat Design AS<br />

Nydamsvej 53<br />

DK – 8362 Hørning<br />

Tel.: +45 86 92 18 33<br />

Fax: +45 86 92 22 18<br />

E-mail: heatdesign@hwam.com<br />

Erklærer hermed, at<br />

Produkt: Type: Nr.:<br />

Brændeovn <strong>HWAM</strong> <strong>Monet</strong> med vandtank 117<br />

er fremstillet i overensstemmelse med bestemmelserne i følgende direktiver:<br />

Reference nr.: Titel:<br />

89/106/EEC Construction Products – CPD<br />

samt følgende harmoniserede standarder:<br />

Nr: Titel: Udgave:<br />

EN 13240 Roomheaters fired by solid fuel 2001<br />

EN 13240/A2 Roomheaters fired by solid fuel 2004<br />

og andre standarder og/eller tekniske specifikationer<br />

Nr: Titel: Udgave: Del:<br />

NS 3058 Lukkede vedfyrte ildsteder Røykudslipp<br />

NS 3059 Lukkede vedfyrte ildsteder Røykudslipp<br />

- Krav<br />

Hørning, d. 21. maj 2007<br />

Torsten Hvam Pedersen<br />

Fabriks- og kvalitetschef


Skorstensfejerpåtegning:<br />

Dato Underskrift<br />

53-6088


Instructions for connection of a stove<br />

with domestic water heating<br />

The mounting and installation of an <strong>HWAM</strong> stove with domestic water heating must follow<br />

DIN 4751, page 2:<br />

1. This kind of heat generators is only permitted to be used with a kettle temperature not<br />

higher than 90°C.<br />

2. The heat exchanger is not permitted to be used for the purpose of heating the domestic<br />

water.<br />

3. The flow pressure available for heating the domestic water must account for at<br />

least 2 atmospheric pressures. If the water conduit falls down under 2 atmospheric<br />

pressures, for example at power failure by your own water supply and at failure<br />

by the circulating pump, then the kettle must immediately be taken out of function.<br />

4. Between the domestic water supply and the thermal drain securities no delimiter of the<br />

flow mass must be installed.<br />

5. As thermal drain security only a certified unit is allowed to be used, fulfilling the following<br />

demands:<br />

• Response temperature 95°C.<br />

• Flow rate with a sensor temperature of 110°C and a differential pressure at the thermo<br />

valve of 1 atmospheric pressure must be at least 200 kg per hour.<br />

• The procurement as well as the proper fitting of the required thermo valve is the responsibility<br />

of the installation firm.<br />

6. The maximum transport pressure in the joint piece is not permitted to exceed 2,5 mmWS.<br />

If this value is exceeded on the assembly place, then the chimney must be provided with<br />

a shunt appliance.<br />

7. The equalization vessel must be equipped at its highest point with an automatically functioning<br />

exhaust valve.<br />

Furthermore, when you fire with solid fuel you have to pay special attention to the following<br />

points:<br />

a. The water pressure in front of the thermal drain security must account for at least 2 atmospheric<br />

pressures, also at open thermal valve.<br />

b. It obliges the user to let a competent person control the thermal drain security at least once<br />

a year. At this occasion the scales and the slop, if any, should be removed from the thermal<br />

drain security. The thermal valve must in this connection be tested on its functionality.<br />

Important!<br />

The heat connection must always be done by a specialist (heating constructor). Only he knows<br />

how to connect the water-leading heat kettle of the stove in a skilled way and according to<br />

the DIN norms.


As to installations that are not done by a specialist we have to decline every warrantee.<br />

As regards professional installation, the person who made the installation is responsible<br />

for the construction.<br />

Connection to central heating system<br />

<strong>HWAM</strong> <strong>Monet</strong> can be connected to a new or an existing central heating system as a supplementary<br />

auxiliary kettle. The water supply must be connected at 4, and the return water from<br />

the woodburning stove must be connected the return line of the system. A part of the water<br />

supply will then circulate through the stove where it is heated further, before it is mixed with<br />

the colder return water.<br />

At the same time it is secured that there is always flow in the stove, no matter if the radiator<br />

thermostats of the heating system should be closed.<br />

Depending on the need for heat, the shunt valve can be set at ”summer position” for quickly<br />

utilization of the stove to heat other rooms with radiators. If the need for heat is not very important<br />

it might be necessary to set the shunt towards “winter position” to involve more water<br />

in the circulation. With the shunt in “winter position” the kettle heats domestic water.<br />

<strong>HWAM</strong> <strong>Monet</strong> connected to a central heating system<br />

1. Automatic aeration<br />

2. Vent<br />

3. Outlet<br />

4. Supply by AVTA valve<br />

5. Floor heating<br />

6. Radiator<br />

7. Supply<br />

18. Return<br />

19. Return conduit<br />

10. Oil-fired burner<br />

11. Hot water<br />

12. Expansion tank<br />

13. Shunt valve<br />

14. Pump


Total heating<br />

Simplified sketch for overall heating<br />

Open<br />

expansion tank<br />

<strong>HWAM</strong><br />

<strong>Monet</strong><br />

F3<br />

Pump<br />

Woodburning<br />

stove circuit<br />

1<br />

Safety valve<br />

Outlet<br />

T<br />

Mix 50°C<br />

M1<br />

Hot water<br />

tank<br />

Radiator circuit<br />

Hot<br />

domestic water<br />

Electric heating element<br />

Supply of cold water<br />

A: Woodburning stove circuit<br />

B: Radiator circuit<br />

C: Floor heating circuit<br />

T: Thermostat KP77<br />

M1: AT mix-valve<br />

1: Thermal drain security<br />

F3: Sensor<br />

Floor heating<br />

Domestic water and heating of rooms<br />

<strong>HWAM</strong> <strong>Monet</strong> can be connected with an automatically working mix-valve and a KP 77 thermostat<br />

intended to start the pumps. The system gives the hot domestic water the highest<br />

priority. Then the radiator circuit is involved for heating the rooms. However the convection<br />

system of the stove quickly gives off heat to the room. You get the best effect if the surplus<br />

heat is converted to floor heat. The floors act as a heat storage slowly giving off the heat<br />

to the rooms. The mix-valve secures that the water tank in <strong>HWAM</strong> <strong>Monet</strong> is always warmer<br />

than 50°C. This gives a better combustion and with that a higher efficiency.<br />

Function<br />

When you light the woodburning stove, the thermostat (T), having a sensor (F3) in the outlet<br />

socket piece of the stove, registers a higher temperature (over 60°C) and starts the circulation<br />

pump. The heat exchanger spiral in the multi-purpose tank is after a short heating<br />

session heating the hot domestic water. When the return water from the multi-purpose tank<br />

exceeds the setting of the mix valve (M1), the supply is little by little changing from + to -. In<br />

that way the radiator circuit is involved in the heating. The floor heating circuit is ruled by a<br />

thermo valve (VT) securing that the floor heat is not getting superheated.<br />

When the stove is burning out the KP77 thermostat closes the pump at 50-55°C. In this<br />

way the circuit stops, before the temperature is down on the about 40°C of the electrical<br />

stick.<br />

Floor heating<br />

circuit<br />

• The system should be frost-proof by a thermo fluid.<br />

• The stove must have the thermal safeguarding drain mounted according to instructions<br />

• There must always be flow in the system so the water tank of the stove can get rid of the<br />

heat.<br />

• The woodburning circuit should be as little as possible and must be well insulated.


Connection to solar collector system<br />

Connection together with solar collector<br />

<strong>HWAM</strong> <strong>Monet</strong> combined with a solar collector system of 4-6 m 2 and a multi-purpose tank<br />

of about 2-300 litres with extra spiral and electric heating element is a very good alternative<br />

to the traditional housing heating with oil-fired burner. During the summer period the solar<br />

collector manages the heating of the domestic water. In colder periods, such as spring and<br />

autumn, it is supplied with <strong>HWAM</strong> <strong>Monet</strong> that gives rapid convection heat to the room, and<br />

supplies the solar collector by heating the water in the upper half of the multi-purpose tank.<br />

During the winter period, <strong>HWAM</strong> <strong>Monet</strong> manages all the heating of the room, partly by<br />

direct convection heat and partly via radiator and floor heating. You will get the best effect<br />

if the surplus heats all the year can be converted to floor heating. The floor heating act as<br />

heat storage, slowly giving off heat to the rooms.<br />

The function of the solar collector system<br />

By heating the solar collector the sensor (F1) registers a higher temperature than the sensor<br />

(F2) in the multi-purpose tank, and the difference thermostat (DT) starts the circulation<br />

pump. The heat-exchanging mantle is lying around the bottom edge of the multi-purpose<br />

tank. In this way the solar collector is exploited in the best possible way, also on days with<br />

little radiation. Thereafter the electric heating element takes care of the further heating. The<br />

solar collector system must out of consideration for staying frost-proof work with antifreeze<br />

mixture.<br />

The function of the woodburning stove circuit<br />

When you light up in the woodburning stove, the thermostat (F3) having a sensor in the<br />

connecting branch of the woodburning stove registers a higher temperature (over 60°C)<br />

and starts the circulation pump. The heat-exchanging spiral in the top of the multi-purpose<br />

tank heats after a short heating session the 80 litres of water on top. When the return water<br />

from the combination tank exceeds the setting of the mix-valve (M1) the supply little by little<br />

changes from + to -. Then the radiator circuit is involved in the heating. The floor heating is<br />

ruled by a thermo valve (VT) securing that the floor heating is not getting too hot.<br />

• The system should be made frost-proof by an antifreeze mixture.<br />

• The safety conduit from the outlet socket piece of the stove must be made according to<br />

the regulations and closing off it is not allowed.<br />

• The surplus heat from the solar collector cannot be spread out to the radiator circuit.<br />

• The woodburning circuit should be as little as possible and must be well insulated.


<strong>HWAM</strong> <strong>Monet</strong> connected with a solar collector system<br />

Expansion<br />

tank<br />

F3<br />

2.<br />

Pump<br />

Woodburing<br />

stove circuit<br />

220V<br />

1.<br />

T<br />

Mix 50°<br />

Outlet<br />

M1<br />

Hot water<br />

tank<br />

8<br />

F2<br />

Electric stick<br />

Fresh water supply<br />

Radiator circuit<br />

F1<br />

220V<br />

DT<br />

Expansion<br />

tank<br />

Pump<br />

Floor heating<br />

Connection with geothermal energy system<br />

DT: Differential thermostat<br />

M1: AT Mix-ventil<br />

T: Thermostat KP 77<br />

Solar collector<br />

circuit<br />

Floor heating<br />

circuit<br />

<strong>HWAM</strong> <strong>Monet</strong> is connected normally to the central heating system between the supply<br />

and the return conduit so that some of the hot supply water is heated further, before it is<br />

mixed with the cold return water. As the hot return water is not good for the heat pump, it is<br />

necessary to insert a thermostat and a three-way valve, so the hot return water circulates<br />

around the pump.<br />

Function<br />

When heated in the stove, the sensor of the thermostat registers rising temperature in the<br />

return conduit, and the three-way valve will close the water around the heat pump and directly<br />

to the supply conduit. Therefore the heat pump will not register any consumption and<br />

will automatically declutch. When the stove burns out, the temperature in the return conduit<br />

will fall, and the three-way valve will once again let the cold water into the heat pump.<br />

<strong>HWAM</strong> <strong>Monet</strong> connected with geothermal heat system<br />

Heat pump<br />

Earth conductor<br />

Expansion<br />

tank<br />

Motor valve Thermostate<br />

M<br />

Sensor<br />

Supply<br />

conduit<br />

Bypass<br />

Pump<br />

Hot service<br />

water<br />

Sensor<br />

Admission<br />

AVTA-valve<br />

Drain<br />

Outlet<br />

1. Thermal drain security<br />

2. Safety valve<br />

Radiator<br />

Return<br />

conduit


Connection with automatically functioning AVTA valve<br />

1. Inlet 3/4" socket piece<br />

2. Outlet 1" socket piece<br />

3. Admission of cooking<br />

water<br />

4. Outlet of cooling water<br />

5. Sensing socket<br />

A. Supply conduit<br />

B. Return conduit<br />

C. E.g. AVTA valve 50 - 90°.<br />

C. Will open at rising<br />

C. temperature<br />

D. Automatic aeration<br />

E. Thermometer<br />

The connection secures together with correct firing the optimal utilization of the water kettle<br />

of the stove. By using a Danfoss AVTA valve 50-90°C, you can secure an outlet temperature<br />

from the stove’s water tank of 70-75°C, and in this way avoid condensed water at the<br />

water tank. At the same time a better secondary combustion is secured, as the fire is not<br />

cooled too much down.<br />

The AVTA valve is mounted at the pipe to the inlet socket piece of the stove (1) and with<br />

the sensor through a 1” cross into to water tank of the stove through the out socket piece<br />

(2). The valve is to be mounted in accordance with the instructions of the factory.<br />

If the outlet pipe and the security conduit go downwards, there should always be mounted<br />

an automatically aeration at the outlet pipe. Like that air pockets are avoided that could<br />

arise by overheating in the lighting stage. If the connection is carried upwards from the<br />

stove, a drain cock should be mounted at the inlet socket piece.<br />

9<br />

F. Manometer, if any<br />

G. Admission with cold<br />

water (domestic water)<br />

H. Thermal circuit breaker<br />

with sensor in connecting<br />

branch (5). Opens at<br />

90°C.<br />

I. Safety valve<br />

J. Outlet of the cooking coil<br />

K. Outlet


Declaration of Conformity<br />

Manufacturer:<br />

<strong>HWAM</strong> Heat Design AS<br />

Nydamsvej 53<br />

DK – 8362 Hørning<br />

Denmark<br />

Tel.: +45 86 92 18 33<br />

Fax: +45 86 92 22 18<br />

E-mail: heatdesign@hwam.com<br />

hereby declares that:<br />

Product: Type:<br />

Wood-burning stove <strong>HWAM</strong> <strong>Monet</strong> with watertank<br />

was manufactured in accordance with the provisions of the following directive:<br />

Reference no. Title:<br />

89/106/EEC Construction Products Directive – CPD<br />

and the following harmonised standards:<br />

No: Title: Version:<br />

EN 13240 Roomheaters fired by solid fuel 2001<br />

EN 13240/A2 Roomheaters fired by solid fuel 2004<br />

and other standards and/or technical specifications<br />

No: Title:<br />

NS 3058 Enclosed wood heaters - Smoke emission<br />

NS 3059 Enclosed wood heaters - Smoke emission<br />

- requirement<br />

Hørning, 21. May 2007<br />

20


Vorschriften für den Anschluss eines Ofens<br />

mit Brauchwasser-Erwärmung<br />

Die Aufstellung eines <strong>HWAM</strong> Kaminofens mit Brauchwasser-Erwärmung muss nach DIN<br />

4751, Blatt 2 erfolgen:<br />

1. Derartige Wärmeerzeuger dürfen nur mit einer höchsten Kesselwasservorlauftemperatur<br />

von 90°C betrieben werden.<br />

2. Der Wärmetauscher darf nicht zum Zweck der Brauchwasserbereitung benutzt werden.<br />

3. Der für den Brauchwasserbereiter zur Verfügung stehende Fließdruck muss mindestens<br />

2 atü betragen. Sofern der Wasserleitungsdruck unter 2 atü abfällt, z.B. Stromausfall bei<br />

Eigenwasserversorgung und Ausfall der Umwälzpumpe, muss der Kessel sofort außer<br />

Betrieb genommen werden.<br />

4. Zwischen Brauchwasserzufluss und thermischen Ablaufsicherungen dürfen keine Durchflussmengenbegrenzer<br />

eingebaut werden.<br />

5. Als thermische Ablaufsicherung darf nur ein bauteilgeprüftes Ventil verwendet werden, das<br />

folgende Anforderungen erfüllt:<br />

• Ansprechtemperatur 95°C.<br />

• Durchflussleistung bei einer Fühlertemperatur von 110°C und einem Differenzdruck am<br />

Thermoventil von 1 atü mindestens 200 kg pro Stunde.<br />

• Die Beschaffung und der sachgemässe Einbau des erforderlichen Thermoventils ist<br />

Pflicht der Installationsfirma.<br />

6. Der maximale Förderdruck im Verbindungsstück darf 2,5 mmWS nicht überschreiten. Wird<br />

dieser Wert am Aufstellungsort überschritten, so ist der Schornstein mit einer Nebenluftvorrichtung<br />

auszustatten.<br />

7. Das Ausgleichsgefäß ist an seinem höchsten Punkt mit einer automatisch wirkenden<br />

Entlüftung auszurüsten.<br />

Ferner ist bei der Verfeuerung von festen Brennstoffen auf folgende Punkte besonders zu<br />

achten:<br />

a) Der Wasserdruck von der thermischen Ablaufsicherung muss auch bei geöffnetem<br />

Thermoventil mindestens 2 atü betragen.<br />

b) Der Betreiber ist verplichtet, die thermische Ablaufsicherung mindestens einmal jährlich<br />

durch einen Sachkundigen prüfen zu lassen. Hierbei muss gegebenfalls die thermische<br />

Ablaufsicherung von Kesselstein und Schmutzwasser gereinigt werden. Das Thermoventil<br />

muss hierzu auf seine Funktionsfähigkeit überprüft werden.<br />

WICHTIG<br />

Der Heizanschluss ist in jedem Falle vom Fachmann zu erstellen (Heizungsbauer). Nur dieser<br />

ist in der Lage, den wassergeführten Kamin-Heizkessel fachgerecht und DIN-Normen<br />

entsprechend zu installieren.<br />

2


Bei nicht fachgerechter Installation müssen wir jegliche Gewährleistung ablehnen.<br />

Für die fachgerechte Installation ist der Errichter der Anlage zuständig.<br />

Anschluss an eine Zentralheizungsanlage<br />

Der <strong>HWAM</strong> <strong>Monet</strong> kann an einer neuen Zentralheizungsanlage angeschlossen werden, oder<br />

an einer bereits vorhandenen Anlage angekoppelt werden und an als ergänzenden Hilfskessel<br />

dienen. Das Vorlaufwasser muss bei 4 angeschlossen werden, und das Rücklaufwasser<br />

des Kaminofens ist an die Retourleitung anzuschließen. Ein Teil des Vorlaufwassers zirkuliert<br />

durch den Ofen und erfährt ein zusätzliche Erhitzung, bevor es sich mit dem kälteren Rücklaufwasser<br />

vermischt.<br />

Dadurch ist gleichzeitig dafür gesorgt, dass im Ofen stets ein Umlauf stattfindet, auch dann,<br />

wenn die Heizkörperthermostate der Heizungsanlage geschlossen sein sollten.<br />

Je nach Wärmebedarf lässt sich das Wechselventil in „Sommerposition“ bringen. Auf diese<br />

Weise kann der Ofen zur schnellen Erwärmung anderer Zimmer mit Heizkörpern genutzt<br />

werden. Bei geringerem Wärmebedarf kann es sich als notwendig erweisen, das Wechselventil<br />

auf „Winterposition“ zu stellen, um größere Wassermengen in den Umlauf einzubringen.<br />

Befindet sich das Wechselventil in „Winterposition“, wird das Nutzwasser im Kessel erhitzt.<br />

<strong>HWAM</strong> Kaminofen an eine Zentralheizungsanlage angeschlossen<br />

1. Entlüftung<br />

2. Thermische Ablaufsicherung<br />

3. Sicherheitsventil<br />

4. Zugang mit AVTA-Ventil<br />

5. Fussbodenwärme<br />

6. Heizkörper<br />

7. Vorlaufleitung<br />

8. Rücklaufleitung<br />

9. Rücklaufleitung<br />

10. Ölbrenner<br />

11. Warmwasser<br />

12. Ausdehnungsgefäß<br />

13. Wechselventil<br />

14. Pumpe<br />

22


Alleinheizung<br />

Grundsatzskizze für Alleinheizung mit <strong>HWAM</strong> <strong>Monet</strong> und Mix-Ventil<br />

<strong>HWAM</strong><br />

<strong>Monet</strong><br />

Ausdehnungsgefäß<br />

F3<br />

2<br />

Pumpe<br />

Kaminofenkreis<br />

1<br />

Abfluss<br />

220V<br />

T<br />

Mix 50°<br />

M1<br />

Warmwasserboiler<br />

Brauchwasser und Raumerwärmung<br />

<strong>HWAM</strong> <strong>Monet</strong> kann an ein automatisch wirkendes Wechselventil angeschlossen werden und<br />

an ein KP77 Thermostat, um die Pumpen in Betrieb zu setzen. Die Anlage bereitet zuerst das<br />

warme Brauchwasser. Danach wird der Heizkörperkreis für die Raumerwärmung eingespeist.<br />

Das Konvektionssystem des Ofens gibt aber schnell Wärme an die Räumen ab.<br />

Die beste Wirkung wird erreicht, wenn die überschüssige Wärme zu Bodenwärme gewechselt<br />

wird. Die Fussböden wirken als ein Wärmelager, das langsam die Wärme an die Räume abgibt.<br />

Das Wechselventil sichert, dass die Wassertemperatur im <strong>HWAM</strong> <strong>Monet</strong> immer über 50°C ist.<br />

Dieses ergibt eine bessere Verbrennung und damit einen höheren Wirkungsgrad.<br />

Funktion<br />

Wenn im Kaminofen geheizt wird, registriert das Thermostat (T), über einen Sensor (F3) im<br />

Abgangsstutzen des Ofens, eine höhere Temperatur (über 60°C) und setzt die Umwälzpumpe<br />

in Betrieb. Die Wechslerspirale im Kombigefäß erhitzt nach kurzer Feuerzeit das wärme Brauchwasser.<br />

Wenn das Rücklaufwasser des Kombigefäßes die Einstellung für das Wechselventil<br />

übersteigt (M1), wechselt der Zugang allmählich von + zu -. Damit wird der Heizkörperkreis<br />

in die Erwärmung aufgenommen. Der Bodenwärmekreis wird von einem Thermoventil (VT)<br />

gesteuert, das sichert, dass die Bodenwärme nicht überhitzt wird.<br />

Wenn der Ofen auf brennt, wird das KP77 Thermostat die Pumpe bei 50-55° C ausschalten.<br />

Damit hält der Kreislauf inne, bevor die Temperatur zu niedrig für den elektrischen Heizstab<br />

wird, etwa 40°C.<br />

2<br />

Frischwasser-<br />

Zuführung<br />

Heizkörperkreis<br />

Warmes<br />

Brauchwasser<br />

Elektrischer<br />

Heizstab<br />

VT<br />

T: Thermostat<br />

M1: Wechselventil<br />

F3: Messfühler<br />

VT: Thermostatventil<br />

1. Thermische Ablaufsicherung<br />

2. Sicherheitsventil<br />

Fussbodenheizungskreis<br />

Fussbodenheizung


• Die Anlage sollte mit Frostschutzmittel geschützt sein.<br />

• Der Ofen muss mit den Vorschriftsmäßigen thermischen Ablaufsicherungen montiert<br />

werden.<br />

• In der Anlage muss immer Durchfluss sein, so das der Wassertank des Ofens die Wärme<br />

abgeben kann.<br />

• Der Kaminofenkreislauf sollte möglichst klein und gut isoliert sein.<br />

Anschluss mit Erdwärme-Kollektoranlage<br />

<strong>HWAM</strong> <strong>Monet</strong> wird auf normale Weise an die Zentralheizungsanlage zwischen den Vorlauf- und<br />

Rücklaufleitungen eingekoppelt, so das ein Teil des warmen Vorlaufwassers ein zusätzliche<br />

Erhitzung erfährt, bevor es sich mit dem kalten Rücklaufwasser vermischt. Da die Wärmepumpe<br />

nicht kaltes Rücklaufwasser verträgt, sind vor der Wärmepumpe einen Thermostat und ein<br />

Wechselventil einzuschieben, damit das warme Rücklaufwasser um die Pumpe zirkuliert.<br />

Funktion<br />

Wenn im Ofen geheizt wird, registriert der Sensor des Thermostats eine steigende Temperatur<br />

in der Rücklaufleitung, das Wechselventil wird dann das Wasser um die Wärmepumpe herum<br />

leiten und direkt in die Vorlaufleitung einleiten. Die Wärmepumpe registriert damit keinen<br />

Verbrauch und schaltet automatisch aus. Wenn der Ofen ausbrennt, wird die Temperatur<br />

in der Rücklaufleitung sinken und das Wechselventil wird wieder das kalte Wasser in die<br />

Wärmepumpe leiten.<br />

<strong>HWAM</strong> <strong>Monet</strong> mit einer Erdwärme-Kollektoranlage zusammengeschlossen<br />

Wärmepumpe<br />

Erdkollektor<br />

Ausdehnungsgefäß<br />

Motorventil Thermostat<br />

M T<br />

Pumpe<br />

Vorlauf<br />

Fühler Rücklauf<br />

Abfluss<br />

2<br />

Fühler<br />

Eingang<br />

1. Thermische Ablaufsicherung<br />

2. Sicherheitsventil<br />

Abgang<br />

AVTA-Ventil<br />

Heizkörper


Anschluss an Sonnenkollektoranlage<br />

Anschluss zusammen mit Sonnenkollektor<br />

<strong>HWAM</strong> <strong>Monet</strong> kombiniert mit einer Sonnenkollektoranlage auf 4-6 m 2 und einem 2-300 Liter<br />

Kombigefäß mit zusätzlicher Spirale und elektrischem Heizstab ist eine besonders gute Alternative<br />

zur traditionellen Wohnungsaufwärmung mit Ölheizung. In der Sommerperiode besorgt<br />

der Sonnenkollektor die Erwärmung des Brauchwassers. In kälteren Perioden, wie Frühjahr<br />

und Herbst, wird mit <strong>HWAM</strong> <strong>Monet</strong> ergänzt, der schnell seine Konvektionswärme zum Raum<br />

abgibt, und hilft dem Sonnenkollektor, das Wasser in der oberen Hälfte des KombiGefäßes<br />

zu erwärmen. In der Winterperiode besorgt <strong>HWAM</strong> <strong>Monet</strong> die ganze Wohnungsaufwärmung,<br />

teils durch direkte Konvektionswärme, und teils durch Heizkörper und Bodenwärme. Die<br />

beste Wirkung bekommt man, wenn das ganze Jahr die Überschusswärme zu Bodenwärme<br />

gewechselt werden kann. Die Bodenwärme funktioniert als ein Wärmelager, das langsam die<br />

Wärme zu den Räumen abgibt.<br />

Die Funktion des Sonnenkollektorkreises<br />

Bei Erwärmung des Sonnenkollektors registriert der Sensor (F1) eine höhere Temperatur<br />

als der Sensor (F2) im Kombigefäß, und der Differenzthermostat startet die Umwälzpumpe.<br />

Der Wechselmantel liegt rund um den kalten Teil des Kombigefäßes. Dadurch wird der Sonnenkollektor<br />

am besten ausgenutzt, auch an Tagen mit kleiner Einstrahlung. Danach sorgt<br />

der elekstrische Heizstab für die weitere Erwärmung. Der Sonnenkollektorkreis muss mit<br />

Frostschutzmittel geschützt sein.<br />

Die Funktion des Kaminofenkreises<br />

Wenn im Ofen geheizt wird, registriert der Thermostat (F3), dessen Fühler im Fühlerstutzen<br />

des Ofens ist, eine höhere Temperatur (über 60° C) und startet die Umwälzpumpe. Die Wechselspirale<br />

im oberen Teil des Kombigefäßes erwärmt nach kurzer Zeit die oberen 80 Liter<br />

Wasser. Wenn das Retourwasser vom Kombigefäß die Einstellung des Wechselventils (M1)<br />

übersteigt, wechselt der Zugang allmählich von + bis -. Damit wird der Heizkörperkreis in die<br />

Erwärmung hineingezogen. Der Fussbodenheizungskreis wird von einem Thermoventil (VT)<br />

gesteuert, der sichert, dass die Fussbodenheizung nicht überhitzt wird.<br />

• Die Anlage sollte mit Frostschutzmittel geschützt sein.<br />

• Der Ofen muss mit den Vorschriftsmäßigen thermischen Ablaufsicherungen montiert<br />

werden.<br />

• Überschusswärme vom Sonnenkollektor kann nicht auf den Heizkörperkreis nicht verteilt<br />

werden.<br />

• Der Kaminofenkreislauf sollte möglichst klein und gut isoliert sein.<br />

2


<strong>HWAM</strong> <strong>Monet</strong> zusammen mit einer Sonnenkollektoranlage angeschlossen<br />

Ausdehnungsgefäß<br />

F3<br />

2.<br />

Pumpe<br />

Kaminofenkreis<br />

1.<br />

Abfluss<br />

T: Thermostat<br />

DT: Differenzthermostat<br />

1: Thermische Ablaufsicherung<br />

2: Sicherheitsventil<br />

220V<br />

T<br />

Mix 50°<br />

M1<br />

Warmwasserlager<br />

Bypass<br />

2<br />

Elektrischer<br />

Heizstab<br />

F2<br />

Warmes<br />

Brauchwasser<br />

Frischwasserzuführung<br />

Heizkörperkreis<br />

F1<br />

220V<br />

DT<br />

Offenes<br />

Ausdehnungsgefäß<br />

Pumpe<br />

Sonnenkollektorkreis<br />

Fussbodenheizungskreis<br />

Fussbodenheizung


Anschluss mit Thermosicherung<br />

und geschlossener Expansion<br />

1. Zugangstutzen 3/4"<br />

2. Abgangstutzen 1"<br />

3. Zugang Kühlwasser<br />

4. Abgang Kühlwasser<br />

5. Fühlermuffe<br />

A. Vorlaufleitung.<br />

B. Rücklaufleitung.<br />

C. Z.B. AVTA-Ventil 50-90°C.<br />

Öffnet bei steigender Temperatur.<br />

D. Automatischer Luftauslass.<br />

E. Thermometer.<br />

F. Eventuelles Manometer.<br />

Der Anschluss sichert zusammen mit einer korrekten Feuerung die optimale Ausnutzung<br />

des Wasserkessels des Ofens. Durch die Verwendung eines AVTA-Ventils 50-90°C wird eine<br />

Abgangstemperatur von 70-75°C gewährleistet und somit wird Kondenswasser auf dem<br />

Kessel vermeidet. Gleichzeitig wird eine bessere Nachverbrennung gesichert, da das Feuer<br />

nicht zu hart heruntergekühlt wird.<br />

Das AVTA-Ventil wird auf das Rohr für den Zugangstutzen des Ofens (1) und mit dem Sensor<br />

durch ein 1" Kreuz in den Wasserkessel des Ofens durch den Abgangstutzen (2) montiert.<br />

Das Ventil muss nach den Anweisungen der Fabrik montiert werden.<br />

Wenn das Abgangsrohr nach unten geleitet wird, sollte ein automatischer Entlüftungshahn auf<br />

das Abgangsrohr immer montiert werden. Dadurch werden Lufttaschen, die bei Überhitzung<br />

in der Einheizungsphase entstehen können, vermieden. Wenn der Anschluss vom Ofen nach<br />

oben geleitet wird, sollte ein Abflusshahn auf den Zugang-stutzen montiert werden.<br />

2<br />

G. Zugang mit kaltem Wasser<br />

(Brauchwasser).<br />

H. Thermosicherung mit Sensor<br />

in Sensorstutzen (5). Öffnet<br />

bei 90°C.<br />

I. Sicherheitsventil.<br />

J. Ablauf von Kühlspirale.<br />

K. Abgangsrohr.


Säkerhetsmässiga krav enligt lagen<br />

Anslutning av en vattentank ska ske i enlighet med arbetsinspektionens publikation nr 42<br />

“Föreskrifter för eldade varmvattensystem” och gällande nationella och lokala standarder.<br />

I dessa hänvisas särskilt till avsnitt 2 om bland annat en säkerhetsledning till en öppen<br />

expansionsbehållare. Säkerhetsledningen ska se till att kaminens värmepanna kan göra<br />

sig av med trycket om den kokar på grund av bristande genomströmning (till exempel vid<br />

strömavbrott).<br />

Om vattnet i tanken/värmepannan kokar trycks vattnet ut genom säkerhetsledningen till den<br />

öppna expansionsbehållaren. Expansionsbehållaren ska därför isoleras vid golv och utlopp<br />

så att det inte kan uppkomma vattenskada. Expansionsbehållaren ska dimensioneras så att<br />

den kan rymma utvidgningen av vattnet i systemet när det värms upp från 0 °C till 100 °C. I<br />

praktiken 4-8 %.<br />

Expansionsbehållaren och säkerhetsledningen ska vara frostsäkrade.<br />

Expansionsbehållarens vattennivå ska kontrolleras regelbundet. När systemet luftats eller om<br />

expansionsbehållaren kokat över ska vattennivån kontrolleras och eventuellt fyllas på.<br />

1. <strong>HWAM</strong> <strong>Monet</strong> med vattentank.<br />

2. Utgångsrör (överst 1”).<br />

3. Säkerhetsledning, minsta invändiga diameter<br />

för stålrör: 21,6 mm, för kopparrör: 19,5<br />

mm. Max. längd: 20 m, max. höjd: 10 m.<br />

Det får inte gå att stänga av säkerhetsledningen.<br />

Se ev. Arbetarinspektionens<br />

publikation nr 42 “Anvisningar för eldade<br />

varmvattensystem”.<br />

4. Öppen expansionsbehållare. Ska kunna<br />

rymma upp till 8 % av systemets totala<br />

vatten-innehåll.<br />

5. Ø 15 mm hävertbrytare.<br />

6. Skvallerledning och överkokning. Dras till<br />

golvet och ska vara snett avskuren.<br />

7. Golvutlopp.<br />

8. Påfyllnings- och avtappningskran.<br />

9. Retur.<br />

10. Tillopp.<br />

11. Automatisk luftutsläpp.<br />

T. Termometer, ska kunna mäta upp till 120<br />

°C<br />

M. Manometer med röd markering vid högsta<br />

vattenpelare. T + M kan kombineras.<br />

28


Säkerhetsledningen, som dessutom kan fungera som returledning till centralpannan, ska<br />

utgå från kaminens toppanslutning. Värmeytan på <strong>HWAM</strong> <strong>Monet</strong> är 0,28 m och därför ska<br />

den anslutas med försänkt säkerhetsledning. Sedan behöver du bara montera en automatisk<br />

avluftare (11) på den högsta punkten efter utloppsanslutningen.<br />

Anslutning till centralvärmeanläggning<br />

<strong>HWAM</strong> <strong>Monet</strong> kan anslutas till en ny centralvärmeanläggning eller kopplas som extra panna<br />

till en befintlig sådan. Framledningsvattnet ska anslutas till 4 och utloppsvattnet från braskaminen<br />

ska anslutas till anläggningens returledning. En viss mängd av framledningsvattnet<br />

kommer att cirkulera i kaminen och värms upp ytterligare innan det blandas med det svalare<br />

returvattnet.<br />

Samtidigt säkerställs att det alltid är genomströmning i kaminen – även om värmeanläggningens<br />

radiatortermostater skulle vara stängda.<br />

Beroende på uppvärmningsbehovet kan shuntventilen ställas in på “sommarinställning”,<br />

vilket innebär att kaminen kan utnyttjas för att snabbt värma upp andra rum med element.<br />

Om behovet av uppvärmning inte är särskilt stort kan du vara tvungen att ställa in shunten<br />

på ”vinterinställning” för att få mer vatten i cirkulation. När shunten står på ”vinterinställning”<br />

värms tappvatten upp med pannan.<br />

<strong>HWAM</strong> <strong>Monet</strong> ansluten till en centralvärmeanläggning<br />

1. <strong>HWAM</strong> <strong>Monet</strong><br />

2. Avluftning<br />

3. Utlopp<br />

4. Inlopp med AVTA-ventil<br />

5. Golvvärme<br />

6. Radiator<br />

7. Framledning<br />

29<br />

8. Retur<br />

9. Retur- och säkerhetsledning<br />

10. Oljepanna<br />

11. Varmt vatten<br />

12. Öppet expansionskärl<br />

13. Shuntventil<br />

14. Pump


Totaluppvärmning<br />

Principskiss för totaluppvärmning<br />

<strong>HWAM</strong><br />

<strong>Monet</strong><br />

Öppet<br />

expansionskärl<br />

Kaminkrets<br />

Varmvattenbehållare<br />

Tappvatten och rumsuppvärmning<br />

<strong>HWAM</strong> <strong>Monet</strong> kan anslutas till en automatisk blandarventil och en KP77-termostat som startar<br />

pumparna. Anläggningen utnyttjar först det varma tappvattnet. Sedan aktiveras radiatorkretsen<br />

för rumsuppvärmning. Kaminens konvektionssystem sprider snabbt värme i rummet. Bäst<br />

verkan blir det om du låter överskottsvärmen växla över till golvvärme. Golven fungerar då<br />

som en värmebuffert som långsamt avger värme i rummen. Blandarventilen ser till att temperaturen<br />

i vattentanken på <strong>HWAM</strong> <strong>Monet</strong> alltid ligger över 50 °C. Det ger bättre förbränning<br />

och därmed högre verkningsgrad.<br />

Funktion<br />

När du tänder brasan i kaminen registrerar termostaten (T), som har en sensor (F3) i kaminens<br />

utloppsanslutning, att temperaturen höjts (över 60 °C) och startar cirkulationspumpen. Efter<br />

en stunds eldning värmer växlarslingan i kombibehållaren upp det varma tappvattnet. När returvattnet<br />

från kombibehållaren överskrider blandarventilens (M1) inställning ändras tillförseln<br />

efterhand från + till -, vilket leder till att radiatorkretsen omfattas av uppvärmningen. Golvvärmekretsen<br />

styrs av en termoventil (VT) som ser till att det inte blir överhettning i golvvärmen.<br />

När elden slocknar i kaminen kommer KP77-termostaten att stänga av pumpen vid 50–55 °C,<br />

vilket i sin tur leder till att cirkulationen stannar innan temperaturen är nere på elstavens<br />

ca 40 °C.<br />

• Anläggningen bör skyddas med frostskydd.<br />

• Säkerhetsledningen från kaminens utloppsanslutning måste alltid dras enligt gällande<br />

föreskrifter och det får inte vara möjligt att spärra den.<br />

• Det måste alltid vara cirkulation i anläggningen så att kaminens vattentank kan bli av med<br />

värmen.<br />

• Kaminkretsen bör vara så liten som möjligt och välisolerad.<br />

0<br />

Utlopp varmvatten<br />

Elstav<br />

Radiatorkrets<br />

Inlopp kallvatten<br />

T: Termostat KP77<br />

M1: AT blandarventil<br />

VT: Termostatventil<br />

Radiator Pump<br />

Golvvärme<br />

Golvvärmekrets


Anslutning till solfångaranläggning<br />

Anslutning till solfångare<br />

<strong>HWAM</strong> <strong>Monet</strong> som kombineras med en solfångaranläggning på 4–6 m 2 och en kombitank på<br />

200–300 l med extra slinga och elstav är ett mycket bra alternativ till vanlig uppvärmning med<br />

oljepanna. Under sommaren sköter solfångaren uppvärmningen av tappvattnet. Under de kyligare<br />

perioderna, som vår och höst, används dessutom <strong>HWAM</strong> <strong>Monet</strong> som snabbt avger konvektionsvärme<br />

i rummet och kompletterar solfångaren genom att värma upp vattnet i kombitankens övre<br />

halva. Under vintern sköter <strong>HWAM</strong> <strong>Monet</strong> all uppvärmning, dels via direkt konvektionsvärme,<br />

dels via radiatorer och golvvärme. Bäst verkan blir det om du låter överskottsvärmen växla<br />

över till golvvärme året runt. Golvvärmen fungerar som en värmebuffert som långsamt avger<br />

värme i rummen.<br />

Solfångarkretsens funktion<br />

Vid uppvärmning av solfångaren registrerar sensorn (F1) högre temperatur än sensorn (F2) i<br />

kombibehållaren och differenstermostaten (DT) startar cirkulationspumpen. Värmeväxlarmanteln<br />

ligger runt kombibehållarens nedre del. Därmed utnyttjas solfångaren bäst, även mulna<br />

dagar. Sedan sköter elstaven den fortsatta uppvärmningen. På grund av risken för frostskador<br />

ska det finnas frostskydd i solfångarkretsen.<br />

Kaminkretsens funktion<br />

När du tänder brasan i kaminen registrerar termostaten (F3), som har en sensor i kaminens<br />

givaranslutning, att temperaturen höjts (över 60 °C) och startar cirkulationspumpen. Efter en<br />

stunds eldning värmer växlarslingan i kombibehållarens topp upp de översta 80 l vatten . När<br />

returvattnet från kombibehållaren överskrider blandarventilens (M1) inställning ändras tillförseln<br />

efterhand från + till -, vilket leder till att radiatorkretsen omfattas av uppvärmningen. Golvvärmekretsen<br />

styrs av en termoventil (VT) som ser till att det inte blir överhettning i golvvärmen.<br />

• Anläggningen bör skyddas med frostskydd.<br />

• Säkerhetsledningen från kaminens utloppsanslutning måste dras enligt gällande föreskrifter<br />

och det får inte vara möjligt att spärra den.<br />

• Överskottsvärme från solfångaren kan inte överföras till radiatorkretsen.<br />

• Kaminkretsen bör vara så liten som möjligt och välisolerad.<br />

<strong>HWAM</strong> <strong>Monet</strong> ansluten till solfångaranläggning<br />

Öppet<br />

expansionskärl<br />

F3<br />

Pump<br />

Kaminkrets<br />

220V<br />

T<br />

Kombi-<br />

DT: Differenstermostat<br />

M1: AT blandarventil<br />

T: Termostat KP 77<br />

behållare<br />

Utlopp<br />

varmvatten F1<br />

Elstav 220V<br />

Solfångarkrets<br />

Tryck-<br />

DT<br />

F2<br />

expansionskärl<br />

Pump<br />

Inlopp kallvatten<br />

Radiator Pump<br />

M1<br />

Bypass<br />

Golvvärmekrets<br />

Golvvärme


Anslutning till jordvärmeanläggning<br />

<strong>HWAM</strong> <strong>Monet</strong> kopplas som vanligt in mellan centralvärmeanläggningens fram- och returledning<br />

så att en del av det varma framledningsvattnet värms upp ytterligare innan det blandas med<br />

det kalla returvattnet. Eftersom värmepumpen inte tål varmt returvatten måste en termostat<br />

och en trevägsventil monteras framför den så att det varma returvattnet leds förbi.<br />

Funktion<br />

När du eldar i kaminen registrerar termostatens sensor att temperaturen i returledningen<br />

stiger och trevägsventilen leder vattnet förbi värmepumpen och direkt till framledningen.<br />

Värmepumpen registrerar alltså inte någon förbrukning och stängs av automatiskt. När elden<br />

slocknar faller temperaturen i returledningen och trevägsventilen släpper åter in det kalla<br />

vattnet i värmepumpen.<br />

<strong>HWAM</strong> <strong>Monet</strong> ansluten till jordvärmeanläggning<br />

Jordslangar<br />

Värmepump<br />

Motorventil Termostat<br />

M T<br />

Sensor<br />

Framledning<br />

2<br />

Öppet<br />

expansionskärl<br />

Utlopp<br />

Sensor<br />

Inlopp<br />

Säkerhetsledning<br />

AVTA-ventil<br />

Radiator<br />

Returledning


Anslutning till automatiskt verkande AVTA-ventil<br />

1. Inlopp 3/4” muff.<br />

2. Utlopp 1” muff.<br />

3. Sensormuff 3/4”<br />

A. Tilloppsledning.<br />

B. Returledning och kaminens<br />

säkerhetsledning med anslutning<br />

till en öppen expansionsbehållare.<br />

C. AVTA-ventil. Öppnar vid stigande<br />

temperatur över 50 °C.<br />

D. Automatiskt luftutsläpp<br />

E. Termometer.<br />

F. Eventuell manometer.<br />

Tillsammans med korrekt eldning säkrar anslutningen ett optimalt utnyttjande av kaminens<br />

vattenpanna. Genom att använda en Danfoss AVTA-ventil 50-90 °C går det att säkerställa en<br />

utloppstemperatur från kaminens vattenbehållare på 70-75 °C och därigenom undvika kondensvatten<br />

på vattentanken. Detta säkerställer längre livslängd för vattentanken när det gäller<br />

korrosion och samtidigt en bättre efterförbränning genom att elden inte kyls ner för snabbt.<br />

AVTA-ventilen monteras på röret till kaminens tilloppsmuff (1) och monteras med sensorn<br />

genom sensormuffen (2). Ventilen ska monteras enligt anvisningarna från fabriken.<br />

Om utloppsröret och säkerhetsledningen går neråt bör det alltid monteras en automatisk<br />

avluftare på utloppsröret. Därmed undviks luftfickor som kan uppstå vid överhettning i antändningsfasen.<br />

Om anslutningen går uppåt från kaminen bör du montera en tappkran på<br />

inloppsanslutningen.<br />

Det är förbjudet och farligt att blockera säkerhetsledningen med kran, pump eller<br />

liknande.


DK-8362 Hørning<br />

heatdesign@hwam.com<br />

www.hwam.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!